PC - Item 3A - Exhibit B DR 17-03 Roof Plan DR 17-03B B A. ATTIC VENTILATION CALCULATION (UPPER ROOF) B. ATTIC VENTILATION CALCULATION (LOWER ROOF) C. TYPICAL VENT AREA ROOF PLAN SCALE: 3/8 " = 1'- 0" ROOM FLOOR BASE WALL CEILING REMARKS CONCRETECARPETTILE / MARBLEHARD WOODWOODPLASTICGYP. BD "X"GYP. BD GYP. BD "WP"GYP. BD "X"GYP. BD GYP. BD "WP"CROWN MOLDINGI II III A B a b FOYER LIVING RM DINING RM FAMILY RM KITCHEN BEDROOMS BATHS MASTER BED W.I.C STAIRWAY GARAGE II II II II II II II II II B B NORTH FINISH SCHEDULE A-4 A DOUBLE HUNG SINGLE / B SLIDING C FIXED D FIXED / STACKEDLA A SWINGING FLUSH B SWINGING C SLIDING DOOR TEMP. GLASS CROWN MOLDING * FOR CEILING HEIGHT ABOVE 12', USE 8" CROWN MOLDING * FOR CEILING HEIGHT UP TO 12', USE 6" BASE BOARD * FOR CEILING HEIGHT ABOVE 10', USE 8" BASE BOARD * FOR 9' OR 10' CEILING HEIGHT, USE 6" * FOR 8' CEILING HEIGHT, USE 4" BASE BOARD NOTES: CALCULATION FOR WHOLE HOUSE VENTILATION FOR INDOOR AIR QUALITY (IAQ) "PANASONIC" WHISPER WARM FV-11VH2 CEILING MT'D EXHAUST FAN 110 CFM @ REMARKS WINDOW SCHEDULE EVERY SLEEPING ROOM SHALL HAVE AN EGRESS WINDOW HAVE A ALL WINDOWS SHALL BE DUAL GLAZED AND LABELED FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE FINISHED FLOOR ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S CONSUMER PRODUCT SAFETY COMMISION MANUFACTURES TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER MATERIALSIZE WINDOW SYMBOLWINDOW TYPEWIDTHHEIGHTVINYLTEMPEREDOBSCUREWINDOW TOP OF 1 2 CLEAR PANEL NO GRID FOR ALL WINDOWS 8' - 0" 8' - 0" 4' - 0" 8' - 0" 8' - 0" 4' - 6" 3 4 5 6 7 8 9 10 11 12 13 14 DOOR SYMBOLDOOR TYPEWIDTHHEIGHTTHICKNESSSOLIDHOLLOWKEYLOCKDEADLOCKDOOR VIEWERPRIVACY LOCKSELF CLOSINGTEMPER GLASSWOODREMARKSMATERIALHARDWARECORESIZE DOOR SCHEDULE A A "431 8' - 0"3' - 0" 2' - 6" "831 "831 A 2' - 8""831 A 2' - 6""831 1 "831 8' - 0"3' - 0"A 2 TIGHT FITTING & SELF CLOSING W WEATHER STRIPPING TIGHT FITTING & SELF CLOSING 8' - 0" 3 "831 4 5 6 7 B "431 8 ICC-ES# ESR-190 EAGLE ROOFING PRODUCT CONCRETE TILE ROOF A-5 1 CALCULATION FOR NATURAL LIGHTING AND VENTILATION AREA NOTE: ALL TYPE 1 VENTS SHOULD BE PAINTED SAME COLOR AS ROOF 2. TOTAL BEDROOM = 4 8' - 0" 8' - 0" 8' - 0" 8' - 0" BE DUAL PANELS ALL GLAZED OPENING SHALL 3. VENT AREA PROVIDED : 2. 6 X 14 EAVE VENT : 6 X 14 / 144 = 0.58 S.F 1. 24" HALF ROUND DORMER LOUVER VENT : 3.14 X 1.002/2 = 1.57 S.F 3. PER ANSI ASHRAS 62.2 EQUATION 4.1A REQUIRED VENTILATION = 4. WE USE EXHAUST FAN: 5. SO, OK 3. VENT AREA PROVIDED : 100 8 B 3' - 0" B B 8' - 0" B 3' - 0"17' - 0" 3' - 0"17' - 0" AS SHOWN A A A A A A A A B B A A A A A A A A a a a a 3/ DOOR FRONT D 6' - 0" 8' - 0" 5' - 0" ALL WINDOWS SHOULD RECESS MINIMUM 2 IN D IRONPROJECT TITLE & LOCATION:DATE SCALE DRAWN JOB SHEET OF SHEETSSTRUCTURAL ENGINEERDESIGNREVISIONS BY 03-18-2017 (TYP 1 OF 4) FOUNDATION WALL TO BE AT LEAST 5 FEET FROM RAIN GUTTER OUTLET DISCHARGE U FACTOR: 0.30, SHGC:0.21 4" BASE BOARD 6" BASE BOARD 8" BASE BOARD FLAT PAINT SEMI GLOSS PAINT 6" CROWN MOLDING 8" CROWN MOLDINGHRECESS DOOR 4" DEEP8' - 0" 5' - 0" 5' - 0" 4' - 0" B 4' - 0" 17' - 0" B D C 5' - 0" No. Exp. CIVILREGISTERED PROFESSION AL E NGI NEERST ATE OF CALIFORNIA DAT H. WONG 62885 (TYP 1 OF 4 UPPER ROOF) LOUVER VENT 24" HALF ROUND DORMER (TYP 1 OF 24 LOWER ROOF) 6" X 14" EAVE VENT NOTES: 3. RADIANT BARRIERS ARE REQUIRED ON ROOF OTHER APPROVED MATERIALS WITH 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM OPENING 2. ATTIC VENTS OPENING SHALL HAVE CORROSION-RESISTANT WITRE MESH OR 1. ALL TYPE 1 VENTS SHOULD BE PAINTED SAME COLOR AS ROOF 4' - 0" 17' - 0"4' - 0"15 3227 / + (4+1) X 7.5 = 69.8 CFM " S.P > 69.8 CFM 5' - 0" 4' - 0" 4' - 0"2' - 0" 5' - 0" 5' - 0"B C 2' - 0"5' - 0" D 4' - 0"5' - 9"8' - 9"W = 4'0", L = 5'0", A = 0'9" 17' - 6"D 2' - 0"W = 4'0", L = 1'6", A = 0'6" B 4' - 0"4' - 0" 4' - 0" B 4' - 0" B 4' - 0"2' - 0"17' - 0" 4' - 0"18' - 4"W = 4'0", L = 4'0", A = 0'6" D 2' - 0"W = 4'0", L = 1'6", A = 0'6" 8' - 0"ROSEMEAD CA 928403058 JACKSON AVENUEATTACHED GARAGENEW 2-STORY SFD & 6-30-18 dathwong@yahoo.com626-627-53931009 WALNUT ST., SAN GABRIEL CA 91776 DAT H. WONG(TYP 1 OF 4) DOWNSPOUT TO LOWER ROOF UPPER ROOF RAIN GUTTER (TYP 1 0F 4) DOWNSPOUT TO GROUND LOWER ROOF RAIN GUTTER 4:12 SLOPE TYP 1. ATTIC AREA TO BE VENTILATED: 1767 S.F 2. VENT AREA REQUIRED: 1767 S.F / 150 = 11.8 SF 4 X 1.57 (TYPE 1) = 6.28 S.F > 50% OF PROVIDED VENT AREA (TYP 1 OF 21 UPPER ROOF) 6" X 14" EAVE VENT 21 X 0.58 (TYPE 2) = 12.20 S.F > 50% OF PROVIDED VENT AREA 4. TOTAL PROVIDED = 18.5 S.F > 11.8 S.F REQUIRED 1. ATTIC AREA TO BE VENTILATED: 1460 S.F 2. VENT AREA REQUIRED: 1460 S.F / 150 = 9.73 SF 24 X 0.58 (TYPE 2) = 13.92 S.F > 50% OF PROVIDED VENT AREA 4. TOTAL PROVIDED = 13.92 S.F > 9.73 S.F REQUIRED 1. TOTAL AREA : 3227 S.F REQUIRED : PROVIDED: OK 1. BEDROOM 1 = 13'0" X 15'6" = 201.5 SF LIGHT (8%) = 201.5 SF X 8% = 16.12 SF VENTILATION (4%) = 201.5 X 4% = 8.06 SF LIGHT = WINDOW (4' X 5') ) = 20 SF VENTILATION = W 1/2 OPENABLE = 10 SF REQUIRED : PROVIDED: OK 2. BEDROOM 2 = 11'0" X 12'0" = 137.5 SF LIGHT (8%) = 137.5 SF X 8% = 11.0 SF VENTILATION (4%) = 137.5 X 4% = 5.5 SF LIGHT = WINDOW (4' X 4'6") = 18 SF VENTILATION = W 1/2 OPENABLE = 9 SF REQUIRED : PROVIDED: OK 3. BEDROOM 3 = 12'0" X 12'6" = 150 SF LIGHT (8%) = 150 SF X 8% = 12 SF VENTILATION (4%) = 150 X 4% = 6.0 SF LIGHT = WINDOW 4' X 4' = 16 SF VENTILATION = W 1/2 OPENABLE = 8.0 SF REQUIRED : PROVIDED: OK 4. MASTER BEDROOM = 15'0" X 18'6" = 277.5 SF LIGHT (8%) = 277.5 SF X 8% = 22.2 SF VENTILATION (4%) = 277.5 X 4% = 11.1 SF LIGHT = WINDOW (4' X 4') + (4' X 4') = 32 SF VENTILATION = W 1/2 OPENABLE = 16 SF 17' - 0"3' - 0"16 D 2' - 0"W = 3'0", L = 1'6", A = 0'6"