PC - Item 3A - Exhibit B DR 17-03 Title Page DR 17-03MECHANICAL ENGINEER
TEL: 626-289-8808 FAX: 626-289-4913
2416 W. VALLEY BLVD ALHAMBRA CA 91803
PERFECT DESIGN
No.
Exp.
CIVILREGISTERED PROFESSION
AL E
N
GI
NEERST
A
TE
OF CALIFORNIA
T-1 dathwong@yahoo.com626-627-53931009 WALNUT ST. SAN GABRILE CA 91776DAT H. WONGAPPLICABLE CODE
SHEET INDEX
T-1
A-1
A-2
A-3
A-4
SECOND FLOOR PLAN
FIRST FLOOR PLAN
ELEVATION & SECTIONS
ROOF PLANS, VENT CALCULATION, WINDOW / DOOR SCHEDULE
A-0 SITE PLAN, LOT COVERAGE, AND FLOOR AREA RATIO
REVISIONS BY
DATE
SCALE
DRAWN
JOB
SHEETDESIGNPROJECT TITLE & LOCATION:CONSULTANT:
SURVEYING
GEOTECHNICAL
STRUCTURAL ENGINEER
FAX: 626-280-9091
TEL: 626-280-9000
ROSEMEAD CA 91770
8748 E. VALLEY BLVD. #L
PETER LEE, INC
AS SHOWN
03-18-2017
OF SHEETS
VICINITY MAP
NORTH
TEL: 714-671-1050 FAX: 714-671-1090
BREA CA 92821
576 E. LAMBERT ROAD
CAL LAND ENGINEERING, INC
PROJECT INFORMATION:
(E) STRUCTURE TO BE DEMOLISHED = 1928 S.F
TYPE OF OCCUPANCY: R3/U
TYPE OF CONSTRUCTION : VB
REQUIREMENTS
STANDARD AND ROSEMEAD FIRE DEPARTMENT
THE SYSTEM SHALL BE INSTALLED PER CRC R313
FIRE SPRINKLERS: REQUIRED
FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION OF SPRINKLER SYSTEM
SPRINKLER PLANS ARE TO BE SUBMITTED TO LA COUNTY FIRE DEPARTMENT
DAT H. WONG
62885
6-30-18
ALL WORK SHALL COMPLY WITH 2014 LOS ANGELES COUNTY AMENDMENTS TO:
* 2013 CALIFORNIA ENERGY CODE
* 2013 CALIFORNIA FIRE CODE
* 2013 CALIFORNIA PLUMBING CODE
* 2013 CALIFORNIA MECHANICAL CODE
* 2013 CALIFORNIA ELECTRICAL CODE
* 2013 CPC
* 2013 C.R.C
* 2013 CALIFORNIA BUILDING CODE
-
-
SCORED C.B.
PRECISION C.B.
SCORED C.B.
PRECISION C.B.6'-0"CONCRETE BLOCK WALL ELEVATION
(N.T.S.)
2
FENCE ELEVATION
(N.T.S.)
14
A-5
1
3'-0"BLOCK WALL AND FENCE PER SEPERATE PERMIT
NOTE:
SPLIT FACE C.B. (GREY COLOR)
SPLIT FACE C.B. (GREY COLOR)ROSEMEAD CA 917703058 JACKSON AVENUEATTACHED GARAGENEW 2-STORY SFD & BLOCK WALL AND FENCE PER SEPERATE PERMIT
NOTE:
C.B PILASTER
16"X16" SPLIT FACE
WROUGHT IRON GATE
2'0"WROUGHT IRON FENCE
15
A-5 16
A-5 MAX1'6"3'6"1'-6" HIGH C.B.W.
5'-4''23'-4''
ROSEMEAD CA 91770
3058 JACKSON AVENUE
NEW 2-STORY SFD & ATTACHED GARAGE
ENGINEERTEL: 714-671-1050 FAX: 714-671-1090
BREA CA 92821
576 E. LAMBERT ROAD
CAL LAND ENGINEERING, INC
PROJECT INFORMATION & SHEET INDEX
LANDSCAPE AREA CALCULATION
GENERAL PLAN DESIGNATION = MEDIUM DENSITY RESIDENTIAL
ALLOWABLE FAR = 10,340 S.F X 0.35 = 3,619 S.F
LOT SIZE = 83.39' X 124' = 10,340 S.F
NUMBER OF STORY : 2
OWNER : JAMES PHAM & HIENTHUC DO
LEGAL DESCRIPTION : TRACT NO. 5152 W 124 FT OF LOT 34
APN #: 5286-023-025
JOB ADDRESS : 3058 JACKSON AVENUE ROSEMEAD CA 91770
TITLE: NEW 2-STORY SFD & ATTACHED GARAGE
9'-3''9'-3''7'-10''7'-10''7'-10''11'-3''
TOTAL LANDSCAPE AREA = 1105+ 4128 = 5233 S.F
FRONT YARD LANDSCAPE AREA = 142+ 358+36+94+475 =1105 S.F > 50% FRONT YARD AREA
FRONT YARD AREA = 2192 S.F
358
475
94
36
142
4128