Loading...
PC - Item 3A - DR 21-03 - Exhibit B35'-0''MECHANICAL ENGINEER TEL: 626-289-8808 FAX: 626-289-4913 2416 W. VALLEY BLVD ALHAMBRA CA 91803 PERFECT DESIGN No. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST AT E OF CALIFORNIA T-1 REVISIONS BY DATE SCALE DRAWN JOB SHEETDESIGNPROJECT TITLE & LOCATION:CONSULTANT: SURVEYING GEOTECHNICAL STRUCTURAL ENGINEER FAX: 626-280-9091 TEL: 626-280-9000 ROSEMEAD CA 91770 8748 E. VALLEY BLVD. #L PETER LEE, INC AS SHOWN OF SHEETS VICINITY MAP NORTHPROJECT INFORMATION: REQUIREMENTS STANDARD AND ROSEMEAD FIRE DEPARTMENT THE SYSTEM SHALL BE INSTALLED PER CRC R313 FIRE SPRINKLERS: REQUIRED FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION OF SPRINKLER SYSTEM SPRINKLER PLANS ARE TO BE SUBMITTED TO LA COUNTY FIRE DEPARTMENT DAT H. WONG 62885 6-30-22 TEL: 714-671-1050 FAX: 714-671-1090 BREA CA 92821 576 E. LAMBERT ROAD CAL LAND ENGINEERING, INC TEL: 714-671-1050 FAX: 714-671-1090 BREA CA 92821 576 E. LAMBERT ROAD CAL LAND ENGINEERING, INC LANDSCAPE AREA CALCULATION - PRECISION C.B. PRECISION C.B.6'-0"CONCRETE BLOCK WALL ELEVATION (N.T.S.) 2 14 A-6 3'-6"- FENCE ELEVATION (N.T.S.) 1 NOTE: 15 A-8 16 A-8 (BROWN COLOR) WROUGHT IRON GATE APPLICABLE CODE * 2019 CALIFORNIA ENERGY CODE * 2019 CALIFORNIA FIRE CODE * 2019 CALIFORNIA PLUMBING CODE * 2019 CALIFORNIA MECHANICAL CODE * 2019 CALIFORNIA ELECTRICAL CODE * 2019 CPC * 2019 C.R.C * 2019 CALIFORNIA BUILDING CODE THE 2019 CALIFORNIA AND GREEN BUILDING CODE ALL WORK SHALL COMPLY WITH 2020 LOS ANGELES COUNTY AMENDMENTS TO 05-18-2021 13'-2' (BROWN COLOR) WROUGHT IRON FENCE HELLMAN AVE.JACKSON AVE.NOT TO SCALE SMOOTH C.B CAP SMOOTH C.B CAP (E) STRUCTURE TO BE DEMOLISHED = 1,166 S.F TYPE OF OCCUPANCY: R3/U TYPE OF CONSTRUCTION : VB GENERAL PLAN LAND USE : LOW DENSITY RESIDENTIAL ZONE: R-1 BLOCK WALL AND FENCE PER ON SEPARATE PERMIT DESIGNERPERMIT NOTES: OF 180 DAYS. A SUCCESSFUL INSPECTION MUST OBTAINED WITHIN 180 DAYS. DAYS AFTER ITS ISSUANCE OR IF THE WORK AUTHORIZED IS SUSPENDED OR ABANDONED FOR A PERIOD 2. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 SHALL AUTOMATICALLY EXPIRE. 1. APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 180 DAYS FOLLOWING THE DATE OF APPLICATION DW HERS RATER VERIFICATION : *VERIFIED DUCT DESIGN * DUCT LEAKAGE TESTING HVAC DISTRIBUTION SYSTEM VERIFICATIONS: * FAN EFFICACY WATTS / CFM * VERIFIED REFRIGERANT CHARGE * VERIFIED SEER * VERIFIED EER * MINIMUM AIRFLOW COLLING SYSTEM VERIFICATIONS: * INDOOR AIR QUALITY VENTILATION * QAULITY INSULATION INSTALLATION (QII) BUILDING-LEVEL VERIFICATIONS: THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY A CERTIFIED HERS RATERS:dathwong@yahoo.com626-627-53935635 ANGELUS AVE SAN GABRIEL CA 91776DAT H. WONGWASOLA ST. NEWMARK AVE. NEWMARK AVE. GRAVES AVE.NEW AVE.DEL MAR AVE.FERN AVE. GARVALIA AVE. GARVALIA AVE.STEVENS AVE.STRATHMORE AVE.DENTON AVE.BRIGHTON AVE.KELBURN AVE.7731 WASOLA STREET 7731 WASOLA 298 361 58 58 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD 7731 WASOLA STREET ROSEMEAD CA 91770 NEW SFD LOT SIZE = 7,975 S.F NUMBER OF STORY : 2 STORIES OWNER : TIMMY CHIANG AND JANE LEE APN: 5289-004-061 LEGAL DESCRIPTION: P.M 367-31-32 LOT 1 JOB ADDRESS : 7731 WASOLA STREET ROSEMEAD CA 91770 TITLE: NEW SFD LINE OF 1ST FLOOR "A""B"SECOND FLOOR 50% OF SECOND FLOOR FRONT FACING WALL CALCULATION 9'-6''16'-0''9'-6''15'-6'' 15'-6'' TOTAL WALL SETBACK AT LEAST 10 FT = 19 FT > 14 FT OK WALL B = 9'6" WALL A = 9'6" 40 % 0F 35 FT = 14 FT TOTAL WALL ON SECOND FLOOR = 35 FT 2666 TOTAL LANDSCAPE AREA = 781 + 2666 = 3,447 S.F > 1,595 S.F OK 0.2 % LANDSCAPE = 7,975 X 0.2 = 1,595 S.F TOTAL LOT AREA = 53 FT X 150.48 FT = 7,975 S.F FRONT YARD LANDSCAPE AREA = 298+58+361+58=781S.F > 50% FRONT YARD AREA 50% FRONT YARD AREA = 530 S.F FRONT YARD AREA = 20 FT X 53 FT = 1,060 S.F 3'6" MAX9'-2''9'-2''4'-10''8'-0''8'-0'' T-1 A-1 A-2 A-3 A-4 A-0 SITE PLAN, LOT COVERAGE, AND FLOOR AREA RATIO PROJECT INFORMATION & SHEET INDEX A-5 WINDOW / DOOR SCHEDULE ROOF PLANS AND VENT CALCULATION SECOND FLOOR PLAN MAIN RESIDENT ELEVATION & SECTIONS FOR MAIN RESIDENT FIRST FLOOR PLAN MAIN RESIDENT SHEET INDEX TO MATCH COLOR OF THE HOUSE 1'-6" HIGH C.B.W.WITH STUCCO FINISH TO MATCH COLOR OF THE HOUSE 16"X16" C.B PILASTER WITH STUCCO FINISH MATCH COLOR OF THE HOUSE C.B.W STUCCO FINISH TO 12'-0''6'-0''20'-0'' 56'-0''26'-0''25'-0''oooooooxxxxxxxxxxWMxxxx1' H RW4' H IRON FENCE 4' H CBW5' H CLF5' H CLF CONC DRIVEWAY CONC DRIVEWAY 1' H PW CONCASPHALT PAVEMENT ASPHALT PAVEMENTCONC SIDEWALKPATIOD/AD/ACONC SIDEWALKCONC SIDEWALK6' H WOOD FENCE EPPOWER PANELCONC(E) 5' H CBW (E) 5' H CBW (E) 4' H CBW (E) 4' H CBW (E)OVERHEAD POWER LINE(E) OVERHEAD POW ER LI NEDATE SCALE DRAWN JOB SHEET OF SHEETS LOT COVERAGE SCALE: 1/8 " = 1'- 0" SITE PLANNORTH SITE PLAN NOTES: A-0 AS SHOWN (1- STORY) SINGLE FAMILY RESIDENCE NEIGHBOR BUILDING (E) REVISIONS BY ON A SEPARATE PERMIT (E) HOUSE TO BE DEMOLISHED SITE PLAN SPECIFICATION PL PLPLPL No. Exp. CIVIL DAT H. WONG 62885 6-30-22 TOTAL COVERAGE PROPOSED PORCH TOTAL FLOOR AREA LOT COVERAGE PROPOSED 2ND. FL LIVING AREA FLOOR AREA LOT SIZE PROPOSED GARAGE & UTILITY 2ND FL / 1ST FL RATIO 9 & UTILITY (N) 2 - CAR GARAGE REGISTERED PROFESSION AL E N GI NEERST ATE OF CALIFORNIA PROJECT TITLE & LOCATION:DESIGNERDESIGNER 546 SF 41 SF 2,127 SF 1,540 SF 1,245 SF 2,785 SF 1 2 CONCRETE WALKWAY (TYP) 3 (N) 5" PCC DRIVEWAY4 5 6 7 8 9 10 11 12 13 14 15 LANDSCAPE AREA (TYP) PER LANDSCAPE PLANS 4 10 (1- STORY) SINGLE FAMILY RESIDENCE NEIGHBOR BUILDING (E) SPRINKLER VALVE PROPOSED MAIN BY THE GAS COMPANY LOCATION TO BE VERIFIED PROPOSED GAS METER LOW IMPACT DEVELOPMENT (LID) SYSTEM USED 2. LANDSCAPING AND LANDSCAPING IRRIGATION 1. RAIN BARREL / CISTERN OF THE 2019 CALIFORNIA RESIDENCEIAL CODE THIS PROJECT SHALL COMPLY WITH THE REQUIREMENTS 1,540 SF SEPARATE PERMIT DEMOLISHED ON A (E) GARAGE TO BE 3 7 TWO (2) 50 GALLONS RAIN BARREL 05-18-2021 FLR ABOVE LINE OF 2ND C. FOR R-2 ONLY ON THE CEILING OF SLEEPING UNITS WITH PERMANENTLY INSTALLED FUEL-BURNING APPLIANCES. B. ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS A. OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING ARE IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) (SECTION 420.4.1AND 420.4.2) SHALL BE INSTALL IN THE FOLLOWING LOCATIONS REQUIREMENTS OF UL 2075.CARBON MONIXIDE ALARMS REQUIRED BY (SECTION R315.1 AND R315.2) OR REQUIREMENTS OF UL 2034. CARBON MONOXIDE DETECTORS SHALL BE LISTED AS COMPLYING WITH THE 15. SINGLE AND MULTIPLE STATION CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH THE ALARM WILL ACTIVATED ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. UNIT, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE 14. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDULA OR SLEEPING FIRE CODE 506. THE LOCATION OF EACH KEY BOX SHALL BE DETERMINED BY THE FIRE INSPECTOR. 13. AN APPROVED KEY BOX, LISTED IN ACCORDANCE WITH UL 1037 SHALL BE PROVIDED AS REQUIRED BY A MINIMUM OF 4" HIGH WITH A MINIMUM STROKE OF 1/2" CONTRAST WITH BACKGROUND, BE ARABIC OR ALPHABETICAL LETTERS AND BE VISIBLE FROM STREET OR ROAD FRONTING PROPERTY. THE NUMBERS SHALL BE BE PROVIDED AND MAINTAINED SO AS TO BE PLAINLY LEGIBLE AND 12. APPROVED BUILDING ADDRESS NUMBER, BUILDING NUMBER OR APPROVED BUILDING IDENTIFICATION SHALL WATER AWAY FROM THE STRUCTURE AND FOUNDATION. 11. ALL SITE DRAINAGE SUCH AS AREA DRAIN AROUND IMPROVEMENTS SHOULD COLLECT AND DIRECT ALL ANY REVISIONS FROM THE SOIL REPORT SHALL BE INCORPORATED INTO THE PLANS AND SPECIFICATIONS AND COMPACTION REPORT SHALL BE SUBMITTED TO AND APPROVED BY THE BUILDING DEPARTMENT. 10.PRIOR TO CALLING FOR BUILDING DEPARTMENT FOUNDATION INSPECTION, PRELIMINARY GRADING 9. FENCES, GATES, AND FIRE SPRINKLERS ARE TO BE INSTALLED WITH SEPARATE SUBMITTAL PERMITS BUILDING, AND DEMOLITION OF EXISTING BUILDING. 8. A SEPARATE PERMIT IS REQUIRED FOR SWIMMING POOLS, SPA, RETAINING WALL, ACCESSORY 7. RESIDENCEIAL FIRE SPINKLERS ARE ALL NEW CONTRUCTION. 6. ALL UTITLITY SERVICES, INCLUDING TELEPHONE AND ELECTRIC POWER, SHALL BE UNDERGROUND. 5. A SEPARATE PERMIT IS REQUIRED TO PERFORMED ALL WORK WITHIN STREET RIGHT OF WAY. DRIVEWAY APRONS AS MAY BE REQUIRED BY THE CITY ENGINEER. 4. REPLACE ALL BROKEN, CRACKED OR UPHEAVED CURB, CURB & GUTTER, SIDEWALK AND 3. DO NOT BLOCK NATURAL DRAINAGE COURSES FROM ADJACENT PROPERTIES. 2. LOT DRAINAGE SHALL BE CONDUCTED TO THE STREET OR AS SHOWN ON THE PLANS. PLANTS SHOULD BE LOW WATER TOLERANT. 1. ALL LANDSCAPING AREAS, INCLUDING THE PARKWAY SHALL BE AUTOMATICALLY IRRIGATED. MAIN RESIDENCE (N) 2 STORY SFD MAIN RESIDENCE MAIN RESIDENCE 2,127 / 7,975 = 26.7% (N) PERMEABLE PAVERS LEGEND: CONCRETE PORCH AS SHOWN ON DETAILS 1 AND 2 ON T-1 SHEET (N) 3'6" HT WROUGHT IRON FENCE AND GATES WITH PILLAR (N) CONCRETE BLOCK WALL 6 FEET MAXIMUM 2 5 4 (N) CONDENSING UNIT ON 4" CONCRETE PAD 3" ABOVE GRADE 8 (N) 24" BOX TREE 12 UNDERGROUND GAS LINE (LOW PRESSURE) 1 14 FRONT SET BACK 1245 / ( 1540 1ST FLOOR + 546 ATTACHED GARAGE = 2086 ) = 59.7% WROUGHT IRON SIDE GATES WITH SCREENING (N) CBW (6' HT MAX) (N) CBW (3'6" HT MAX) DECIDED BY SCE COMPANY & PANEL EXACT LOCATION TO BE PROPOSEDD 200 AMP ELECTRIC METER PROPOSED 1ST FL. LIVING AREA PROPOSED 1ST FL. LIVING AREA PROPOSED F.A.R WATER HEATER PROPOSED TANKLESS SETBACK REAR LATERAL (E) SEWER (N) SEWER CHECK VALVE 6 15 dathwong@yahoo.com626-627-53935635 ANGELUS AVE. SAN GABRILE CA 91776DAT H. WONG(35% ALLOWABLE = 2791 S.F) 2,785 SF / 7,975 S.F = 34.9% < 35.0 % PORCH = 41 S.F 2ND FLR LV. AREA = 1,245 S.F 1ST FLR LV. AREA = 1,540 S.F SETBACKSIDE SETBACKSIDE 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD PATIO 18'-6''6'-6'' 25'-0'' TO BE UPGRADED (E) WATER METER PROTECT IN PLACE (E) CBW 3 REMOVE (E) IRON FENCE 7 8 11 (N) WATER LINE 13 (N) DRIVEWAY APPROACH PER SPPWC STD PLAN 110-2 REMOVE (E) DRIVEWAY APPROACH AND CONSTRUCT 50 FT X 150.48 FT = 7,975 SF NOTE: STUCCO FINISH TO MATCH WITH STUCCO COLOR OF THE HOUSE ALL EXISTING CBW AND NEW CBW WITHIN THE PROPERTY SHOULD BE MG A/CA/CW/H W/H 53.00'53.00'150.49' 150.50'CL25'25'STWASOLA 5'-6"15'-0"13'-6"15'-6"35'-0"15'-6"6'-0"5'-6"17'-0"26'-0" 49'-6" 26'-0"44'-0"14'-0"21'-0"4'-0"10'-6"10'-6"9'-6"4'-6"11'-0"2'-6"2'-0"2'-6"10'-6"9'-0"6'-6"6'-6"6'-6"9'-0"7'-0"6'-0"13'-0"9'-0"13'-0"20'-0"20'-0"PROJECT TITLE & LOCATION:A-1 AS SHOWN REVISIONS BY DESIGNDATE SCALE DRAWN JOB SHEET OF SHEETS 4 FLUORESCENT LIGHT (TYP.). MEDICINE CABINET (TYP.). MIRROR (TYP.). 1 2 3 MIN. 22" WIDE TEMPERED GLASS DOOR FOR SHOWER (TYP.) 6 5 7 8 14 15 16 17 18 19 20 21 32 33 34 35 36 37 38 39 40 47 ALL BATHROOMS FLOORING SHALL BE LAID OVER 15 LB. FELT (TYP.) CEILING LIGHT WELL WITH FLORESCENT LIGHTS. DISWASHER, OVEN, OR MICROWAVE SPACES. AUTOMATIC GARAGE DOOR OPENER WITH REMOTE CONTROL AND LIGHT FIXTURE 8'-0 "X 8'0" GARAGE DOOR. EQUIPPED WITH LASER BEAM SAFETY RELEASE. WASHER AND DRYER WIH TWO SEPARATE 20 AMP CIRCUITS. A/C DISCONNECT SWITCH. HOSE BIBB WITH NON-REMOVABLE BACKFLOW DEVICE. 3' 6" HT. GUARDRAIL (TYP.) 34"-38" HT. HANDRAIL (TYP.) RETURN AIR GRILL FOR FIRST FLOOR A/C SYSTEM RETURN AIR GRILL FOR SECOND FLOOR AC SYSTEM. FLOOR PLAN SPECIFICATION 23 22 24 " SOLID WOOD CORE OR 20 MIN. RATING DOOR WITH SOLID JAMB. DOOR TO8 31 BE TIGHT FITTING WITH WEATHER STRIPPING AND SELF-CLOSING. 48 49 STANDARDS 119(D). AND WIRING TO PANEL. EXTERIOR LIGHT FIXTURE WITH SENSOR ( PER 2013 ENERGY EFFICIENCY 50 ARE MADE OF BRASS AND W/O SLIP JOINTS (TYP.) 12" MIN ACCESS PANEL EXCEPT WHERE CONCEALED FIXTURE CONNECTION RESISTANT & LABELLED SAFETY GLAZING (TYP.). WITHIN 5' OF DRAIN OF SHOWER OR BATHROOM FLOOR TO BE SHATTER PROVIDE 6'-0" HT. NON-ABSORBENT WALLS ADJACENT TO SHOWER. WINDOWS SHOWER ENCLOSURE WITH APPROVED SHATTER RESISTANT MATERIALS AND ENCOMPASS 30 INCH (762 MM) DIAMETER CIRCLE. RECEPTOR SHALL BE NOT LESS THAN 1024 SW IN OF FLOOR AREA, AND BE LABELED CATEGORY ii. SWING DOOR OUTWARD. NET AREA OF SHOWER SHALL BE MOISTURE RESISTANT. GLASS ENCLOSURE DOORS AND PANELS MUST EQUAL TO 70" ABOVE DRAIN. MATERIAL OTHER THAN STRUCTURAL ELEMENTS WALL COVERINGS IN SHOWERS AND TUBS TO BE CEMENT PLASTER, TILE OR EMBEDDED IN CONCRETE PAD. 3" DIA. X 3' HT. STEEL POST ABOVE GROUND FILLED WITH CONCRETE AND 2'0" DUCT DIRECTLY TO OUTSIDE AIR. 18" HT. WOOD PLATFORM FOR WATER HEATER. PROVIDE MIN. 26 GAUGE GALV. LESS THAN 1 FOOT-CANDLE (11 LUX). ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT 1-HR RATED FIRE RESISTANCE WALL WITH TYPE "X" 5/8 GYP. BD. 51 DRAIN OR TOWWARD THE MAIN VEHICLE ENTRY. MATERIALS, AND THE AREA USED TO PARK VEHICLES SHALL SLOPE TO A GARAGE FLOOR SURFACES SHALL BE OF AN APPROVED NON CUMBUSTIBLE 9 10 11 12 13 25 26 27 28 29 41 42 44 45 30" DIA. MIN CLEARANCE SPACE FOR SHOWER (TYP). CABINET ABOVE (TYP.). GARBAGE DISPOSAL. REFRIGERATOR SPACE. DRYER VENT TO OUTSIDE AIR WITH DAMPER. PROVIDE 4" DIA. SMOOTH GALV. CLOSET DOOR. LIGHTING TO BE CONNECTED TO SWITCH AT SECOND FLOOR. LIGHTING TO BE CONNECTED TO SWITCH AT FIRST FLOOR. 30" X 22" ATTIC ACCESS FRONT DOOR TO BE RECESSED 4" DEEP. 5/8" GYP. BP. TYPE 'X' FINISHED FOR ALL USABLE SPACE AREA BELOW STAIRWAY UNPROTECTED COMBUSTIBLE MATERIAL OR 24" TO METAL VENTILATION HOOD. HOOD VENT TO OUTSIDE AIR. PROVIDE 30" CLEARANCE ABOVE RANGE TO ADJACENT TO OR SUPPORTING THE DWELLING. " GP. BD TYPE "X" ON GARAGE WALLS, CEILING, POSTS AND BEAMS8 5 TIGHT FITTING, SELF-LATCHING AND SELF-CLOSING. SOLID WOOD CORE OR 1-HR FIRE RATED ACCESS COVER, COVER TO BE 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM AND MIN. 1-3/8" THICK USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. IN SHOWERS OR TUB-SHOWERS, MAX TEMP. OF 120 F TO BE PROVIDED BY THE 30 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM. (TYP.) ATTIC FURNACE "PANASONIC" WHISPER WARM FV-11VH2 - CEILING MT'D EXHAUST FAN ---110 CFM 46 DABMAR LIGHTING FIXTURE (GM-135). A MINIMUM OF 4" HIGH WITH A MINIMUM STROKE OF 1/2" CONTRAST WITH BACKGROUND, BE ARABIC OR ALPHABETICAL LETTERS AND BE VISIBLE FROM STREET OR ROAD FRONTING PROPERTY. NUMBERS SHALL BE INSTALL ADDRESS NUMBER PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND 31 16'-0" X 8'-0 GARAGE DOOR. EQUIPPED WITH LAZER BEAM SAFETY RELEASE. No. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST ATE OF CALIFORNIA DAT H. WONG 62885 6-30-22 DESIGNER & UTILITY 2 -CAR GARAGE 14'0" X 13'6" SCALE: 1/4 " = 1'- 0"NORTHKITCHEN 15'6" X 13'6" LIVING ROOM 15'0" X 13'3"DINING ROOM PWDR OPEN TO CEILING FOYER 5'0" X 5'6" W.I.C 5'0" X 6'6" PORCH 1 WINDOW EGRESS BEDROOM 1 CLEAN OUT S WP S3 B AFCI 30"x30" ATTIC ACCESS WALL SWITCH, SINGLE POLE 3-WAY SWITCH FLUORESCENT LIGHT EXHAUSTED FAN, 50 CFM MIN. SENSOR LIGHT A/C DISCONNECT SWITCH GARBAGE DISPOSAL RETURN AIR CEILING LIGHT WALL LIGHT HANGING LIGHT (METAL HALIDE LAMP) DOOR BELL MULTIMEDIA OUTLET TELEPHONE PC NETWORK TV HOSE BIBB SYMBOL DESCRIPTION G TELEPHONET ELECTRICAL RECEPTACLE WITH TAMPER RESISTANT AND HALLWAY ROOM, DINING ROOM, LIVING ROOM, CLOSET AND TAMPER RESITANTIN ALL BEDROOM, FAMILY RECEPTACLE WITH ARC FAULT CIRCUIT INTERUPTION GFCI RECEPTACLE WITH TAMPER RESITANT SUPPLY AIR REGISTER CLIMATE CONTROL FOR HV/AC GASKET OR CAULKED BETWEEN HOUSING & CEILING COVER (IC); AIR TIGHT (AT) AND SEALED WITH A APPROVED FOR ZERO CLEARANCE INSULATION RECESS LIGHT (METAL HALIDE LAMP) SHALL BE LIGHT WITH REMOTE CONTROL AUTOMATIC GARAGE DOOR OPENER AND CLIMATE M EV 05-18-2021 UP TEMPERED PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE FUTURE ELECTRIC VEHICLE CHARGING AS "EV" CAPABLE. PROTECTION DEVICE SPACE DESERVED FOR SERVICE PANEL SHALL IDENTIFY THE OVERCURRENT TERMINATE AT A LISTED CABINET IN THE GARAGE. THE DIAMETER, ORIGINATES AT MAIN SERVICE PANEL AND THE RACEWAY SHOULD NOT BE LESS THAN 1-INCH INSIDE CIRCUIT DEDICATED FOR ELECTRIC VEHIVLE CHARGER. PRE-WIRE 40 AMP CIRCUIT 208 / 240 VOLT BRANCH ENERGY REQUIREMENT: TO BE USED IN CALIFORNIA. SOCKET. ALL LED'S SHOULD BE ON THE LIST OF THE ENERGY COMMISSION APPROVED LIST 7. ALL LED'S SHOULD HAVE GU-24 LINE VOLTAGE SOCKET OR USE IC RATED WITH 4 PIN BASE 6. FOR ALL KITCHEN LIGHTING, 50% OF ALL WATTAGE MUST BE HIGH EFFICACY. 5. ALL BATHROOM OUTLETS SHALL BE GROUND-FAULT CIRCUIT TYPE. RATED FOR INSULATION CONTACT (IC-RATED). 4. LUMAINARIES THAT ARE RECESSED INTO INSULATED CEILINGS ARE REQUIRED TO BE MOTION SENSOR WITH AN INTERGRAL PHOTO CONTROL. 3. ALL OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY OR CONTROLED BY DIMMERS OR MANUAL SWITCH ON AUTOMATIC VACANCY SENSOR OFF. 2. ALL ROOMS (EXCEPT BATHROOMS GARAGE, AND UTILITY ROOMS) ARE TO BE ELECTRIC AND CONTROLLED BY A VACANCY SENSOR. 1. BATHROOM, GARAGE, LAUNDRY, UTILITY AND CLOSET LUMINARIES SHALL HAVE HIGH EFFICACY FOR ELECTRIC VEHICLE WILL ACCOMODATE AN ADDITIONAL 40 AMP DEDICATED BRANCH CIRCUIT WHICH 200 AMP ELECTRIC PANEL EXACT LOCATION TO BE APPROVED BY EDISON PLANNER ELECTRICAL NOTES: MONOXIDE DETECTOR INTERCONNECTED HARD WIRE W/ BATTERY BACK-UP SMOKE/CARBON BATH 1 9'0" X 5'0" RP A-4 B A-4 B 1 2 @ CEILING 45 48 24 25 36 37 13 32 46 5 9 6 8 10 51 21 A-9 1 3 7.75" MAX A-9 19 A-3 A A-4 A FIRST FLOOR PLAN - MAIN RESIDENCE CHANDELIER LIGHT SHALL BE SECURED TO METAL ELECTRICAL BOX. 26 FLR ABOVE LINE OF 2ND 773138 CALGREEN NOTES: 3. DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE USED. CGBSC 4.504.2.4 SALVAGE, PER CGBSC 4.408.1. 2. A MINIMUM OF 65 PERCENT OF THE CONSTRUCTION WASTE GENERATED AT THE SITE SHALL BE DIVERTED TO RECYCLE OR 1. EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING PER CGBSC 4.506.1 MECHANICAL NOTE: FLAMMABLE VAPOR IGNITION RESITANT, PER MC 305.1 1. WASHER AND DRYER LOCATED IN GARAGE HSALL BE INSTALLED AT LEAST 18-IN ABOVE THE FLOOR UNLESS LISTED AS PLUMBING NOTES: 2. ALL HOSE BIBS MUST HAVE AN APPROVED ANTI-SIPHON DEVICE PERMIT ISSUANCE. STANDARDS. CPVC WATER REQUIRES A CERFICATION OF COMPLIANCE AS SPECIFIED IN SEC 604.1.1(D) OF THE CPC PRIOR TO SEC. 604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURES RECOMMENDED INSTALLATION PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF 1. WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING CODE. CONDENSING UNIT ON 4" CONCRETE PAD WITH 3"ABOVE GRADE. ENERGY MANAGEMENT CONTROL SYSTEM. SENSOR, PHOTO CONTROL AND AUTOMATIC SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR OVERRIDE TO ON AND ONE OF THE FOLLOWING: CONTROLLED BY PHOTOCELL AND MOTION 10. ALL OUTDOOR LIGHT SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT REQUIRED TO BE INTERGAL (I.E BUILT-IN) II. A HUMIDITY CONTROL MAY BE A SEPERATE COMPONENT TO THE EXHAUST FAN AND IS NOT MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. RANGE OF LESS OR EQUAL TO 50% TO A MAXMUM OF 80%. A HUMIDITY CONTROL MAY UTILIZE I. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVELY HUMIDITY BE CONTROL BY A HUMIDITY CONTROL. B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BUILDING. A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE 9. EXHAUST FAN IN BATHROOMS LIVING ROOM, FAMILY ROOM AND BEDROOM ETC. SHALL BE HIGH EFFICACY OR BE CONTROLLED 8. ALL PERMANTLY INSTALLED LIGHTING IN OTHER ROOMS SUCH AS HALLWAYS, DINNING ROOM, TAMPER RESITANT GFCI WATER-PROOF RECEPTACLE W/ VACANCY SENSOR SWITCH VS S RANGE REQUIRES A MINIMUM OF 40-AMP WIRE (#8 COPPER OR #6 ALUMINUM), PER CEC 220-19 L. CLOTHES DRYERS AND ELECTRIC RANGES SHALL HAVE A 4-WIRE GROUNDED ELECTRICAL OUTLET PER CEC 250.140. ELECTRIC K. ALL NEW LIGHTING SHALL BE HIGH EFFICACY PER CEC TABLE 150.0(K)1A J. ALL ELECTRICAL OUTLETS SHALL BE TAMPER RESISTANCE (CHILD PROOF). THAN 24" FROM A RECEPTACL OUTLET. I. INSTALL RECEPTACLES IN KITHCHEN EVERY 4' ABLOVE THE COUNTER. NO POINT ON THE KITHCHEN WALL SHALL BE LOCATED MORE H. INSTALL GARAGE AND KITHCHEN RECEPTACLES AT +42" ABOVE FINISH FLOOR. BUILT-IN REFRIGERATOR OR FREEZER, FURNACE, AIR CONDITIONING OR BUILT IN HEATERS, WITH A MOTOR OF 1/4 H.P OR LARGER. G. PROVIDE A SEPARATE 20 AMP CIRCUIT FOR EACH FIX APPLIANCE, SUCH AS GARGAGE DISPOSAL, DISHWASHING MACHINE, DRYER, F. PROVIDE AN ISOLATED BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.. E. PROVIDE A SEPERATE #12 AWG WIRE BRANCH CIRCUIT FOR THE RECPTACL AT GARGARE DISPOSAL. D. PROVIDE 20 AMP CIRCUIT FOR THE RECEPTACLES IN THE LAUNDRY ROOM. C. PROVIDE TWO 20 AMP SMALL APPLIANCE CIRCUITS FOR THE RECEPTACLES IN THE KITHCHEN. B. PROVIDE AN ISOLATED 20 AMP CIRCUIT FOR RECEPTACLES IN EACH BATHROOM. LARGER REBAR, BOND TO GAS AND WATER LINES. A. INSTALL GROUNDING WITH 20' UFER GROUND IN FOOTING, EITHER NO. 4 AWG OR LARGER BARE COPPER CONDUCTOR OR #4 OR MAX 199,000 BTU/H "TAKAGI" TANKLESS WATER HEATER- MODEL T-H3 - MIN 15,000 BTU/H 3 3 5 3 3 2433 1 19'0" X 9'0"dathwong@yahoo.com626-627-53935635 ANGELUS AVE. SAN GABRIEL CA 91776DAT H. WONG43 2 R =7 '-0" 1 STORAGE UNDER STAIR 4'-0"9 A-9 6 6 6 6 6 3 4 5 7 11 A-9 14 1210 15 6" MAX PATIO 14'0" X 5'6"7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD FAMILY ROOM REF WASHER DRYER W/H W/H A/CA/C3'6" X 8' ISLAND PANTRY COUNTER DW ENTERTAINMENT 3'-6"16'-0"16'-0"12'-6"15'-6"8'-6"7'-6" 5'-6"3'-0"10'-6"2'-6"7'-6"5'-0"2'-0"11'-0"2'-6" 5'-6" 49'-6"6'-6"3'-0"2'-0"4'-0"3'-6"8'-0"8'-0"9'-6"9'-6"16'-0"9'-6"35'-0"2'-6"4'-0"2'-0"11'-0"2'-6"3'-6"9'-0"4'-6"5'-0"10'-0"3'-0"2'-6" 18'-0"9'-6"12'-6"4'-0"15'-6" 44'-0"15'-0"7'-0"9'-0"2'-0"18'-0"17'-0"35'-0"2'-0"PROJECT TITLE & LOCATION:AS SHOWN REVISIONS BY DESIGNDATE SCALE DRAWN JOB SHEET OF SHEETS No. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST ATE OF CALIFORNIA DAT H. WONG 62885 6-30-22 DESIGNER WINDOW EGRESS CLEAN OUT S WP S3 B AFCI 30"x30" ATTIC ACCESS WALL SWITCH, SINGLE POLE 3-WAY SWITCH FLUORESCENT LIGHT EXHAUSTED FAN, 50 CFM MIN. SENSOR LIGHT A/C DISCONNECT SWITCH GARBAGE DISPOSAL RETURN AIR CEILING LIGHT WALL LIGHT HANGING LIGHT (METAL HALIDE LAMP) DOOR BELL MULTIMEDIA OUTLET TELEPHONE PC NETWORK TV HOSE BIBB SYMBOL DESCRIPTION G TELEPHONET ELECTRICAL RECEPTACLE WITH TAMPER RESISTANT AND HALLWAY ROOM, DINING ROOM, LIVING ROOM, CLOSET AND TAMPER RESITANTIN ALL BEDROOM, FAMILY RECEPTACLE WITH ARC FAULT CIRCUIT INTERUPTION GFCI RECEPTACLE WITH TAMPER RESITANT SUPPLY AIR REGISTER CLIMATE CONTROL FOR HV/AC GASKET OR CAULKED BETWEEN HOUSING & CEILING COVER (IC); AIR TIGHT (AT) AND SEALED WITH A APPROVED FOR ZERO CLEARANCE INSULATION RECESS LIGHT (METAL HALIDE LAMP) SHALL BE LIGHT WITH REMOTE CONTROL AUTOMATIC GARAGE DOOR OPENER AND CLIMATE M EV 05-18-2021 DN PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE FUTURE ELECTRIC VEHICLE CHARGING AS "EV" CAPABLE. PROTECTION DEVICE SPACE DESERVED FOR SERVICE PANEL SHALL IDENTIFY THE OVERCURRENT TERMINATE AT A LISTED CABINET IN THE GARAGE. THE DIAMETER, ORIGINATES AT MAIN SERVICE PANEL AND THE RACEWAY SHOULD NOT BE LESS THAN 1-INCH INSIDE CIRCUIT DEDICATED FOR ELECTRIC VEHIVLE CHARGER. PRE-WIRE 40 AMP CIRCUIT 208 / 240 VOLT BRANCH MONOXIDE DETECTOR INTERCONNECTED HARD WIRE W/ BATTERY BACK-UP SMOKE/CARBON 46 5 9 6 8 TAMPER RESITANT GFCI WATER-PROOF RECEPTACLE W/ VACANCY SENSOR SWITCH VS S 12'0" X 12'0" BEDROOM 2 14'0" X 12'0" BEDROOM 3 15'6" X 15'6" MASTER BEDROOM LOFT SCALE: 1/4 " = 1'- 0"NORTHSECOND FLOOR PLAN - MAIN RESIDENCE 5'0" X 15'6" W.I.C 9'0" X 5'0" W.I.C 5'0" X 5'0" W.I.C BATH 2 BATH 3 A-2 dathwong@yahoo.com626-627-53935635 ANGELUS AVE. SAN GABRIEL CA 91776DAT H. WONGMASTER BATH 10 14 14 66 13 4 6 6 9 10 11 12 8 12 7 A-4 A A-3 A A-4 B A-4 B TEMPERED TEMPERED TEMPERED TEMPEREDWINDOW EGRESS WINDOW EGRESS 5 5 6 6 6 6 6 6 6 8 4 FLUORESCENT LIGHT (TYP.). MEDICINE CABINET (TYP.). MIRROR (TYP.). 1 2 3 MIN. 22" WIDE TEMPERED GLASS DOOR FOR SHOWER (TYP.) 6 5 7 8 14 15 16 17 18 19 20 21 32 33 34 35 36 37 38 39 40 47 ALL BATHROOMS FLOORING SHALL BE LAID OVER 15 LB. FELT (TYP.) CEILING LIGHT WELL WITH FLORESCENT LIGHTS. DISWASHER, OVEN, OR MICROWAVE SPACES. AUTOMATIC GARAGE DOOR OPENER WITH REMOTE CONTROL AND LIGHT FIXTURE 8'-0 "X 8'0" GARAGE DOOR. EQUIPPED WITH LASER BEAM SAFETY RELEASE. WASHER AND DRYER WIH TWO SEPARATE 20 AMP CIRCUITS. A/C DISCONNECT SWITCH. HOSE BIBB WITH NON-REMOVABLE BACKFLOW DEVICE. 3' 6" HT. GUARDRAIL (TYP.) 34"-38" HT. HANDRAIL (TYP.) RETURN AIR GRILL FOR FIRST FLOOR A/C SYSTEM RETURN AIR GRILL FOR SECOND FLOOR AC SYSTEM. FLOOR PLAN SPECIFICATION 23 22 24 " SOLID WOOD CORE OR 20 MIN. RATING DOOR WITH SOLID JAMB. DOOR TO8 31 BE TIGHT FITTING WITH WEATHER STRIPPING AND SELF-CLOSING. 48 49 STANDARDS 119(D). AND WIRING TO PANEL. EXTERIOR LIGHT FIXTURE WITH SENSOR ( PER 2013 ENERGY EFFICIENCY 50 ARE MADE OF BRASS AND W/O SLIP JOINTS (TYP.) 12" MIN ACCESS PANEL EXCEPT WHERE CONCEALED FIXTURE CONNECTION RESISTANT & LABELLED SAFETY GLAZING (TYP.). WITHIN 5' OF DRAIN OF SHOWER OR BATHROOM FLOOR TO BE SHATTER PROVIDE 6'-0" HT. NON-ABSORBENT WALLS ADJACENT TO SHOWER. WINDOWS SHOWER ENCLOSURE WITH APPROVED SHATTER RESISTANT MATERIALS AND ENCOMPASS 30 INCH (762 MM) DIAMETER CIRCLE. RECEPTOR SHALL BE NOT LESS THAN 1024 SW IN OF FLOOR AREA, AND BE LABELED CATEGORY ii. SWING DOOR OUTWARD. NET AREA OF SHOWER SHALL BE MOISTURE RESISTANT. GLASS ENCLOSURE DOORS AND PANELS MUST EQUAL TO 70" ABOVE DRAIN. MATERIAL OTHER THAN STRUCTURAL ELEMENTS WALL COVERINGS IN SHOWERS AND TUBS TO BE CEMENT PLASTER, TILE OR EMBEDDED IN CONCRETE PAD. 3" DIA. X 3' HT. STEEL POST ABOVE GROUND FILLED WITH CONCRETE AND 2'0" DUCT DIRECTLY TO OUTSIDE AIR. 18" HT. WOOD PLATFORM FOR WATER HEATER. PROVIDE MIN. 26 GAUGE GALV. LESS THAN 1 FOOT-CANDLE (11 LUX). ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT 1-HR RATED FIRE RESISTANCE WALL WITH TYPE "X" 5/8 GYP. BD. 51 DRAIN OR TOWWARD THE MAIN VEHICLE ENTRY. MATERIALS, AND THE AREA USED TO PARK VEHICLES SHALL SLOPE TO A GARAGE FLOOR SURFACES SHALL BE OF AN APPROVED NON CUMBUSTIBLE 9 10 11 12 13 25 26 27 28 29 41 42 44 45 30" DIA. MIN CLEARANCE SPACE FOR SHOWER (TYP). CABINET ABOVE (TYP.). GARBAGE DISPOSAL. REFRIGERATOR SPACE. DRYER VENT TO OUTSIDE AIR WITH DAMPER. PROVIDE 4" DIA. SMOOTH GALV. CLOSET DOOR. LIGHTING TO BE CONNECTED TO SWITCH AT SECOND FLOOR. LIGHTING TO BE CONNECTED TO SWITCH AT FIRST FLOOR. 30" X 22" ATTIC ACCESS FRONT DOOR TO BE RECESSED 2" DEEP. 5/8" GYP. BP. TYPE 'X' FINISHED FOR ALL USABLE SPACE AREA BELOW STAIRWAY UNPROTECTED COMBUSTIBLE MATERIAL OR 24" TO METAL VENTILATION HOOD. HOOD VENT TO OUTSIDE AIR. PROVIDE 30" CLEARANCE ABOVE RANGE TO ADJACENT TO OR SUPPORTING THE DWELLING. " GP. BD TYPE "X" ON GARAGE WALLS, CEILING, POSTS AND BEAMS8 5 TIGHT FITTING, SELF-LATCHING AND SELF-CLOSING. SOLID WOOD CORE OR 1-HR FIRE RATED ACCESS COVER, COVER TO BE 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM AND MIN. 1-3/8" THICK USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. IN SHOWERS OR TUB-SHOWERS, MAX TEMP. OF 120 F TO BE PROVIDED BY THE 30 30" X 30" ATTIC ACCESS WITH 30" CLEAR HEADROOM. (TYP.) ATTIC FURNACE "PANASONIC" WHISPER WARM FV-11VH2 - CEILING MT'D EXHAUST FAN ---110 CFM 46 DABMAR LIGHTING FIXTURE (GM-135). A MINIMUM OF 4" HIGH WITH A MINIMUM STROKE OF 1/2" CONTRAST WITH BACKGROUND, BE ARABIC OR ALPHABETICAL LETTERS AND BE VISIBLE FROM STREET OR ROAD FRONTING PROPERTY. NUMBERS SHALL BE INSTALL ADDRESS NUMBER PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND 31 16'-0" X 8'-0 GARAGE DOOR. EQUIPPED WITH LAZER BEAM SAFETY RELEASE. FOR ELECTRIC VEHICLE WILL ACCOMODATE AN ADDITIONAL 40 AMP DEDICATED BRANCH CIRCUIT WHICH 200 AMP ELECTRIC PANEL EXACT LOCATION TO BE APPROVED BY EDISON PLANNER CHANDELIER LIGHT SHALL BE SECURED TO METAL ELECTRICAL BOX. CONDENSING UNIT ON 4" CONCRETE PAD WITH 3"ABOVE GRADE. MAX 199,000 BTU/H "TAKAGI" TANKLESS WATER HEATER- MODEL T-H3 - MIN 15,000 BTU/H 43 BELOW TO OPEN FLR BELOW LINE OF 1ST 5 8 5 8 6 46 4 5 8 6 46 4 35 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD 13'-8"6'-0" 12'-0"10'-0"10'-0"25'-4"20'-0"PROJECT TITLE & LOCATIONNo. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST ATE OF CALIFORNIA AS SHOWN DATE SCALE DRAWN JOB SHEET OF SHEETSDESIGNREVISIONS BY DAT H. WONG 6-30-22 62885 05-18-2020 A-3 BEDROOM MASTER " = 1'- 0"16 3SCALE: SECTION B-B - MAIN RESIDENCE " = 1'- 0"16 3SCALE: SECTION A-A - MAIN RESIDENCE 2 X ROOF RAFTER (SEE STRUCTURE FOR SIZE TYP) " STUCCO FINISH OVER METAL LATH & FELT (TYP)87 2 X CEILING JOIST (SEE STRUCTURE FOR SIZE TYP) " PLYWOOD "CDX" SUB-FLOOR (TYP)32 19 CEILING, POSTS, AND BEAMS FOR SEPARATION " GYPSUM BD. TYPE "X" ON GARAGE WALLS, 8 510 9 8 7 6 5 4 3 2 1 R-19 INSULATION FOR EXTERIOR WAL (TYP) R-19 INSULATION FOR FLOOR AREA SECTION SPECIFICATION PLYWOOD SHEATHING "32 15CONCRETE TILE ROOF OVER 30LBS FELT ON —" R-30 INSULATION FOR CEILING AREA (TYP) " GYPSUM BOARD FINISH (TYP)8 5INTERIOR LIVING ROOM DESIGNER" = 1'- 0"16 3SCALE: " = 1'- 0"16 3SCALE: " = 1'- 0"16 3SCALE: " = 1'- 0"16 3SCALE: PL (N) C.B.W SETBACK PL (N) C.B.W PL EAST ELEVATION - MAIN RESIDENCESOUTH ELEVATION - MAIN RESIDENCE WEST ELEVATION - MAIN RESIDENCENORTH ELEVATION - MAIN RESIDENCE SETBACK ELEVATION SPECIFICATION 1 2 3 4 5 #26 G.A.G.I. FLASHING AT VALLEY (TYP) (DUNN EDWARD PAINTS, DEW 317-LRV 88 DAY LILY) (TYP.) PRE CAST CONCRETE MOLDING 6 7 8 9 10 11 DABMAR LIGHT FIXTURE (GM-135) (TYP) ELEVATION SPECIFICATION 12 DOORS) (DUNN EDWARD PAINTS, DEW 317-LRV 88 DAY LILY) (TYP) SECTIONAL LONG PANEL STEEL GARAGE DOOR W/ WINDOW (CLOPAY GARAGE (DUNN EDWARD PAINTS, DEW 317-LRV 88 DAY LILY) (TYP) PRE CAST CONCRETE WAINSCOT UNDER EAVE MOLDING (DUNN EDWARD PAINTS, DEW 317-LRV 88 DAY LILY) (TYP) 13 12 BUILDING HEIGHT5 8"8"1st F.F. IRON DOOR JELDWEN VINYL WINDOW WITH CLEAR PANEL NO GRID (TYP) NO GRIDS (TYP) JELDWEN VINYL SLIDING DOOR WITH WITH CLEAR PANEL 2 X FASCIA (DUNN EDWARD PAINTS,DEW 317-LRV 88 DAY LILY (TYP) CULTURE STONE) (ICC-ES ESR-1364) STONE VENEER (GRAY COBBLEFIELD) 7 PL (N) C.B.W PL (N) C.B.W T.P FAMILY RMT.P OFFICE SETBACK 9'-0''T.P 2nd F.F. 1st F.F. T.P 9'-0''FRONT SETBACK TYP4 12 3 PORCH A-8 8 A-8 7 21 A-9 BEDROOM 1 GARAGE W.I.C.BATH 1 BATH 3 BEDROOM 3 BATH 2 BEDROOM 2 21 A-921 A-9 BEDROOM 1 BATH 2 W.I.C.HALLWAY 1 TYP 1'-6"TYP 1'-6" TYP 1'-6" TYP 1'-6" TYP 1'-6" TYP 1'-6" TYP 1'-6" TYP 1'-6" 2 3 4 6 8 9 10 11 dathwong@yahoo.com626-627-53935635 ANGELUS AVE. SAN GABRIEL CA 91776DAT H. WONG13 1 2 4 5 6 7 8 9 10 2 A-8 6 A-8TYP 10 A-8 TYP 4 12 TYP 4 12 TYP 4 12 TYP 4 12 TYP4 12 TYP4 12 TYP4 12 INSTALL WEIGHT : 10 PSF (TYP) BEL AIR, 4679 LIGHT GRAY RANGE APPROX. (EAGLE ROOFING PRODUCT ICC-ES ESR-1900) TYPE CONC. TILE ROOF OVER 30 LBS. FELT ON ROOF SHEATHING 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD DIRECTION SAND FINISH) (TYP) SMOOTH FINISH FRONT HOUSE ONLY FACING SOUTH OTHER 7#8" EXTERIOR STUCCO (LA HABRA STUCCO) (434 FALLBROOK (BASE 200)) FAMILY ROOM NOTE: OTHER DIRECTION SHOULD RECESS 2 IN MINIMUM. SEE DETAILS 11,12,13 / A-6 ALL WINDOWS IN SOUTH ELEVATION FACING STREET SHOULD RECESS 4 IN MINIMUM PROJECT TITLE & LOCATIONNo. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST ATE OF CALIFORNIA AS SHOWN DATE SCALE DRAWN JOB SHEET OF SHEETSDESIGNREVISIONS BY DAT H. WONG 6-30-22 62885 A DOUBLE HUNG SINGLE / B SLIDING C FIXED D FIXED / STACKEDLA REMARKS WINDOW SCHEDULE EVERY SLEEPING ROOM SHALL HAVE AN EGRESS WINDOW HAVE A ALL WINDOWS SHALL BE DUAL GLAZED AND LABELED FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE FINISHED FLOOR ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S CONSUMER PRODUCT SAFETY COMMISION MANUFACTURES TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER MATERIALSIZE WINDOW SYMBOLWINDOW TYPEWIDTHHEIGHTVINYLTEMPEREDOBSCUREWINDOW TOP OF 1 2 CLEAR PANEL NO GRID FOR ALL WINDOWS 8' - 0" 8' - 0" 17' - 0" 3 4 5 7 8 9 10 11 12 13 8' - 0"B 5' - 0" B 5' - 0" B 8' - 0" B B B ALL WINDOWS SHOULD RECESS MINIMUM 2 IN U FACTOR: 0.30, SHGC:0.20 4' - 0" 5' - 0" 3' - 0" 17' - 6" A 2' - 0" 4' - 0" 3' - 0" 5' - 0" 5' - 0" 4' - 0" 5' - 0"17' - 0" C 3' - 0"3' - 0" 3' - 0" B 3' - 0"4' - 0"17' - 0" 2' - 0"8' - 0" A SWINGING FLUSH B SWINGING C SLIDING DOOR TEMP. GLASS DOOR FRONT D HB B ROOM FLOOR BASE WALL CEILING REMARKS CONCRETECARPETTILE / MARBLEHARD WOODWOODPLASTICGYP. BD "X"GYP. BD GYP. BD "WP"GYP. BD "X"GYP. BD GYP. BD "WP"CROWN MOLDINGI II III A B a b FOYER LIVING RM DINING RM FAMILY RM KITCHEN BEDROOMS BATHS MASTER BED W.I.C STAIRWAY GARAGE II II II II II II II II II B B FINISH SCHEDULE CROWN MOLDING * FOR CEILING HEIGHT ABOVE 12', USE 8" CROWN MOLDING * FOR CEILING HEIGHT UP TO 12', USE 6" BASE BOARD * FOR CEILING HEIGHT ABOVE 10', USE 8" BASE BOARD * FOR 9' OR 10' CEILING HEIGHT, USE 6" * FOR 8' CEILING HEIGHT, USE 4" BASE BOARD NOTES: A A A A A A A A B B A A A A A A A A a a a a 4" BASE BOARD 6" BASE BOARD 8" BASE BOARD FLAT PAINT SEMI GLOSS PAINT 6" CROWN MOLDING 8" CROWN MOLDING 05-18-2021 A-4 6 B 4' - 0"4' - 0"17' - 0"14 B 5' - 0"4' - 0"17' - 0"DESIGNERdathwong@yahoo.com626-627-53935635 ANGELUS AVE SAN GABRIEL CA 91776DAT H. WONGC 6' - 0"3' - 0" 17' - 0" 4' - 0"2' - 0"B 17' - 0" C 2' - 0"2' - 0"17' - 0"DOOR SYMBOLDOOR TYPEWIDTHHEIGHTTHICKNESSSOLIDHOLLOWKEYLOCKDEADLOCKDOOR VIEWERPRIVACY LOCKSELF CLOSINGTEMPER GLASSWOODREMARKSMATERIALHARDWARECORESIZE DOOR SCHEDULE A A "431 8' - 0"3' - 0" 2' - 6" "831 "831 A 2' - 8""831 A 2' - 2""831 1 "831 8' - 0"3' - 0"A 2 TIGHT FITTING & SELF CLOSING W WEATHER STRIPPING TIGHT FITTING & SELF CLOSING 3 "831 4 5 6 7 B "431 8 8' - 0" 8' - 0" 5' - 0" 8' - 0" BE DUAL PANELS ALL GLAZED OPENING SHALL 6' - 0" 8' - 0" 5' - 0" D IRON8' - 0" C 5' - 0" A A A 3' - 5""431 6' - 8" 6' - 8" 6' - 8" 2' - 6" 2' - 8" "831 "831 9 10 11 13 12 A 3' - 0"6' - 8""831 A 2' - 2""831 6' - 8" TIGHT FITTING & SELF CLOSING 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD A-5 CALCULATION FOR NATURAL LIGHTING AND VENTILATION AREA AS SHOWNPROJECT TITLE & LOCATION:DATE SCALE DRAWN JOB SHEET OF SHEETSDESIGNREVISIONS BY No. Exp. CIVILREGISTERED PROFESSION AL E NGI NEERST ATE OF CALIFORNIA DAT H. WONG 62885 6-30-22 dathwong@yahoo.com626-627-53935635 ANGELUS AVE. SAN GABRILE CA 91776DAT H. WONGA. ATTIC VENTILATION CALCULATION (UPPER ROOF) B. ATTIC VENTILATION CALCULATION (LOWER ROOF) C. TYPICAL VENT AREA CALCULATION FOR WHOLE HOUSE VENTILATION FOR INDOOR AIR QUALITY (IAQ) "PANASONIC" WHISPER WARM FV-11VH2 CEILING MT'D EXHAUST FAN 110 CFM @ NOTE: ALL TYPE 1 VENTS SHOULD BE PAINTED SAME COLOR AS ROOF 3. VENT AREA PROVIDED : 100 8 2785/ + (4+1) X 7.5 = 65.35 CFM 4 X 1.57 (TYPE 1) = 6.28 S.F > 50% OF PROVIDED VENT AREA 20 X 0.58 (TYPE 2) =11.60 S.F > 50% OF PROVIDED VENT AREA ENGINEER(TYP 1 0F 4) DOWNSPOUT TO GROUND LOWER ROOF RAIN GUTTER (TYP 1 OF 4 UPPER ROOF) LOUVER VENT 24" HALF ROUND DORMER ICC-ES# ESR-1900 EAGLE ROOFING PRODUCT CONCRETE TILE ROOF ROOF PLAN SCALE: 3/8 " = 1'- 0"NORTH (TYP 1 OF 3 LOWER ROOF) LOUVER VENT 24" HALF ROUND DORMER (TYP 1 OF 12 LOWER ROOF) 6" X 14" EAVE VENT (TYP 1 OF 20 UPPER ROOF) 6" X 14" EAVE VENT 05-18-2021 MAIN RESIDENCE MAIN RESIDENCE 1. ATTIC AREA TO BE VENTILATED: 1,814 S.F 2. VENT AREA REQUIRED: 1,814 S.F / 150 = 12.09 SF 2. VENT AREA REQUIRED: 1020 S.F / 150 = 6.80 SF 3 X 1.57 (TYPE 1) = 4.71 S.F > 50% OF PROVIDED VENT AREA 12 X 0.58 (TYPE 2) =6.96 S.F > 50% OF PROVIDED VENT AREA 1. TOTAL AREA : 2785 S.F 2. TOTAL BEDROOM = 4 3. VENT AREA PROVIDED : 2. 6 X 14 EAVE VENT : 6 X 14 / 144 = 0.58 S.F 1. 24" HALF ROUND DORMER LOUVER VENT : 3.14 X 1.002/2 = 1.57 S.F 3. PER ANSI ASHRAS 62.2 EQUATION 4.1A REQUIRED VENTILATION = 4. WE USE EXHAUST FAN: 5. SO, OK 3/ A-8 1 REQUIRED : PROVIDED: OK 1. BEDROOM 1 = 14'0" X 13'6" = 189 SF LIGHT (8%) = 189 SF X 8% = 15.12 SF VENTILATION (4%) = 189 X 4% = 7.56 SF LIGHT = WINDOW (5' X 5') = 25 SF VENTILATION = W 1/2 OPENABLE = 12.5 SF NOTES: 4. PROVIDE RAIN GUTTERS AND DOWNSPOUTS ON HOUSE FOR RAIN BARRELS. 3. GUTTER AND DOWNSPOUNTS SHOULD BE THE SAME COLOR AS THE FASCIA BOARD OTHER APPROVED MATERIALS WITH 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM OPENING 2. ATTIC VENTS OPENING SHALL HAVE CORROSION-RESISTANT WITRE MESH OR 1. ALL TYPE 1 VENTS SHOULD BE PAINTED SAME COLOR AS ROOF 4:12 SLOPE TYP 4. TOTAL PROVIDED = 17.88 S.F > 12.09 S.F REQUIRED 1. ATTIC AREA TO BE VENTILATED: 1,020 S.F 4. TOTAL PROVIDED = 11.67 S.F > 6.80 S.F REQUIRED " S.P > 65.35 CFM REQUIRED : PROVIDED: OK 2. BEDROOM 2 = 12'0" X 12'0" = 144.0 SF LIGHT (8%) = 144.0 SF X 8% = 11.52 SF VENTILATION (4%) = 144.0 X 4% = 5.76 SF LIGHT = WINDOW (5' X 3') + (3' X 4')= 27 SF VENTILATION = W 1/2 OPENABLE = 13.5 SF REQUIRED : PROVIDED: OK 3. BEDROOM 3 = 14'0" X 12'0= 168.0 SF LIGHT (8%) = 168.0 X 8% = 13.44 SF VENTILATION (4%) = 168.0 X 4% = 6.72 SF LIGHT = WINDOW (5' X 4') + (3' X 4')= 32 SF VENTILATION = W 1/2 OPENABLE = 16.0 SF REQUIRED : PROVIDED: OK 4. MASTER BEDROOM = 15'6" X 15'6" =240.25 SF LIGHT (8%) = 240.25 SF X 8% = 19.22 SF VENTILATION (4%) = 240.25 X 4% = 9.61 SF LIGHT = WINDOW (4' X 4') + (4' X 4') = 32 SF VENTILATION = W 1/2 OPENABLE = 16 SF 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD REVISIONS BY DATE SCALE DRAWN JOB SHEET OF SHEETSCLIENT/OWNERDESIGN24" D.C. each side. (LOAD-BEARING) nailed to top and bottom plates at 7" o.c. Stagger joints 1-7/8" long, 0.0915" shank,‚" heads, 7" o.c. Wallboard 2 x 4 wood studs spaced 24" o.c., with 6d coated nails applied parallel with of at right angles to each side of One layer†" type X gypsum wallboard or veneer base2"STUCCO FINISH ‡" EXTERIOR 4"EXT. STUCCO "8 7 WINDOW STUD (TYP.) 2X6 STUCCO FINISH " EXTERIOR87 NOTE: CONC. MOLDING 2 X 4 PRECAST STUCCO FINISH " EXTERIOR87 WINDOW WDO. FRAMING 2X4 STUD (TYP.) 2X6 PRECAST CONC. SILL RECESSED 2" HEADER 2 X 4 WDO. FRAMING WINDOW 2 X 4 WDO. FRAMING 2 X 6 WALL FRAMING INSULATION R-15 (2X6 MIN. FOR PLUMBING WALL) 2 X STUD @ 16" O.C. (SEE STUCTURAL PLAN) PLYWOOD IF OCCURS OVER PLYWOOD) (2-LAYERS GRAD "D" FELT LATH METALEXT. STUCCO "87 GARAGE EXTERIOR WALL) (5/8" TYPE X GYP. BD. FOR " X GYP. BD.85 WDO. FRAMING 2X4 (SEE STRUCTURAL PLAN) PLYWOOD IF OCCURS FOR BATHROOM) WATER RESISTANT TYPE UNDER STAIR SIDE & USABLE SPACE (TYPE X GYP. BD. FOR GARAGE " X GYP. BD.85 PLUMBING WALL) (2X6 MIN FOR 2XSTUD @ 16" O.C. " GYP. BD.8 5 HABITABLE AREA BETWEEN GARAGE & R-13 INSULATION FOR BATHROOM) WATER RESISTANT TYPE UNDER STAIR SIDE & USABLE SPACE (TYPE X GYP. BD. FOR GARAGE " X GYP. BD.85 2 x FJ @ 16" O.C. FOR FLOOR COVERING SEE FIN. SCHEDULE " GYPCRETE43 T&G PLYWD " CDX3219 OVERHANG (IF OCCURS) OVER GARAGE OR R-19 INSULATION 2 ND FLOOR HABITABLE AREA BETWEEN GARAGE & R-19 INSULATION ASSEMBLY DESCRIPTION: Gypsum Wallboard, Wood Studs Fire Test: Approx. Weight: 7 psf Thickness: 4-7/8" UL R3501-47, 48, 9-i7-65; Sound Test: NGC 2404, 10-14-70 Design U314 R1319-129.7-22-70 Design U309 Gypsum Wallboard, Wood Studs GA File No. WB 3510 Fire Rating: 1-Hour 4" TYP.6" MIN.TO WD. BLK'G MET HANGER & NAILED VENT PIPE W/SHT. COMPOUND FLASHING 2 X BLK'G 2 X RAFTER VENT PIPE (TYP.) FLASHING AROUND 24 GA. G.I. ALL AROUND SEALANT 4" TYP. ROOF SHEATHING ROOF TILE ROOFING FELT ROOF RAFTER RIDGE A35 @ EA RAFTER PLYWD SHEATH'G R-30 INSULATION EAVE VENTS WOOD RAFFLE @ EAVE VENT OCCURS OMIT 2 X BLK'G " GYP. BD.85 R-13 INSULATION (2-LAYER OVER PLYWOOD) GRADE "D" FELT ON METAL LATH OVER " EXTERIOR STUCCO87 2 X BLK'G/EAVE VENT 2X8 FASCIA 2X4 OVER W/ KICKOUT ROOF EDGING SET IN MASTIC 24 GAGI FLASHING Z BAR FLASHING PLYWD SHEATH'G 1-30# FELT OVER 15/32" CONC. TILE ROOF ON 1-30# FELT OVER 15/32" GRADE "D" FELT (2-LAYER OVER PLYWOOD) " EXTERIOR STUCCO FIN. ON METAL LATH OVER87 Z-BAR FLASHING 24 GA. G.I. FLASHING CONC. TILE PLYWD. SHEATHING LEDGER 2 X STUDS 2X ROOF RAFTER IS 3/12 OR LESS) (2-30# FELT WHERE SLOPE 1-30# FELT (2-LAYER OVER PLYWOOD) METAL LATH OVER GRADE "D" FELT " EXTERIOR STUCCO ON87 ROOF SHEATHING FLASHING CHANNEL 24 GA. GI. 2X ROOF RAFTER 2 X STUDS PLYWD SHEATH'G 1-30# FELT OVER 15/32" CONC. TILE ROOF ON COUNTER FLASHING SET IN MASTIC 24 GAGI FLASHING W/ KICKOUT ROOF EDGING 2X6 FASCIA 2X4 OVER (2-LAYER OVER PLYWOOD) GRADE "D" FELT ON METAL LATH OVER " EXTERIOR STUCCO87 2 X STUDS 2 X FLAT 2-2 X R.R. ROOF SHEATHING PLYWD SHEATH'G 1-30# FELT OVER 15/32" CONC. TILE ROOF ON " TYPE X GYP. BD.8 5 INSULATION R-13 (2X6 MIN. FOR PLUMBING WALL) 2 X STUD @ 16" O.C. (SEE STUCTURAL PLAN) PLYWOOD IF OCCURS OVER PLYWOOD) (2-LAYERS GRAD "D" FELT LATH METAL INTERIOR 2 X TRUSS VALLEY BEAM 36" WIDE BASE UNDRLAYMENT FLASHING 24 GA. G.I. 1-30 # FELT CONC. TILE A-6 COUNTER FLASHING BLOCK OPEN. 3. ADJUSTABLE FLUE DAMPER FOR GAS MIN. 6 SQ.IN., EQUIPPED WITH A DAMPER. 2. COMBUSTION AIR INTAKE (FROM OUTSIDE), DOOR AT THE FIREBOX OPENING. 1. OPERABLE & CLOSABLE METAL OR GLASS PROVIDE: PROVIDE GLASS DOOR AT OPENING. INSTALLED PER MANUFACTURER'S SPECIFICATIONS. MODEL: BGD36CF (TEST TO ANSI Z21.88) NAPOLEON DIRECT VENT GAS FIREPLACE OF FIRE-BOX MATERIAL AROUND OPENING 12" MIN. NON-COMBUSTIBLE MIN. 1-1/2" CLEAR PIPE VENTCONSTRUCTION & CHIMNEY AIR SPACE BETWEEN ALL MAINTAIN 2" MIN. CLEAR @ (EVERY 10" INTERVAL) SHEET METAL FIRE STOP RAFTER ROOF " PLWD. SHEATHING21 TWISTED ST 6236 CHASE COVER STORM COLLAR TERMINATION CAPS 19 ROOF MIN. 4" ASPHALT SHINGLE CONFORMED TO FLEXIBLE FLASHING FLASHING COUNTER 2XR.R. FLASHING ALTERNATIVE FLEXIBLE PLYWD SHEATH'G 1-30# FELT OVER 15/32 CONC. TILE ROOF ON PROPERTY LINE REBAR IN GROUT FILLED CELLS W/ #4 @32" O.C. VERT. & HORIZ. 6" CONC. BLK. WALL @18" O.C. OMIT 1ST COURSE HEADJOINT 1 #4 T&B 12" 9" FL 2%12"15"OF 4 FULLY GROUT FILLED CELLS 1 #4 VERT @ EA. CORNER TOTAL 16" SQ. CONC. PILASTER 1 #4 T&B 16"12"15"FL 2% 16"16"A A EQ EQ PROPERTY LINE REBAR IN GROUT FILLED CELLS W/ #4 @32" O.C. VERT. & HORIZ. 6" CONC. BLK. WALL @18" O.C. OMIT 1ST COURSE HEADJOINT 1 #4 T&B EQ EQ FL 2% 9" 12"18"24"6'-0" OR 4'-0"(NO RETAINING SOIL)SCALE N.T.S. SCALE N.T.S. SCALE N.T.S. 13 13 No. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST ATE OF CALIFORNIA ROOF CHASE INLET AIR TELESCOPE 3" MIN. OVERLAP SECTION & CHASE COVER. 10" MAX. SPACE BEWEEN CHIMNEY WITH 11" MIN. DIA. HOLE FLAT FLASHING OR CHASE COVER PIPE FOR CHASE TYPE INSTALLATION INCORPORATES LONGER DUCT & FLUE SCL OR SQLB CHIMNEY CAP DESIGN COMBUSTIBLES ABOVE ROOF LINE SPACE CLEARANCES TO MAINTAIN CHIMNEY SYSTEM AIR SCREW BRACKETS, 3 PLACES. CHIMNEY CAP SUPPORT AREA 4 TIMES THAT OF THE CHIMNEY. DESA SPARK ARRESTER W/ A NET APPROVAL. PERMITTED WITHOUT MANUFACTURER'S NO OTHER ARCHITECTURAL FEATURE IS NOTE: STUCCO FINISH PRE-FAB FIREPLACE FLUE 2X4 STUD " PLYWD SHEATHING ON21 TWISTED ST 6236 " PLYWD. SHEATHING21 RAFTER ROOF 20 NO SCLAE VALLEY DETAIL ROOF PARALLEL TO WALL 5 4BLOCK WALL SECTION HOUSE & GARAGE SEPARATION WALL VENT PIPE DETAIL 14 9 10 3ROOF PERPENDICULAR TO WALL8 RIDGE / HIP DETAIL 1 2X4 OVER 2X8 EAVE DETAIL 2 FENCE WALL SECTION 15CHIMNEY FRAMING CONNECTION 19 CHIMNEY CAP INSTALLATION 18 RAKE DETAIL 22 DIRECT VENT GAS FIREPLACE 17 RECESSED WINDOW (SECTION VIEW) CHIMNEY FLASHING 20 PILASTER SECTION 16 2" RECESSED WINDOW (PLAN VIEW)11 4" RECESSED WINDOW (PLAN VIEW)12FIREPLACE/CHIMNEY WALL 21 6EXTERIOR WALL INTERIOR WALL 7 13 FLOOR / CEILING ASSEMBLY BLOCK WALL AND FENCE PER SEPERATE PERMIT NOTE: BLOCK WALL AND FENCE PER SEPERATE PERMIT NOTE: BLOCK WALL AND FENCE PER SEPERATE PERMIT NOTE: 05-28-2021DESIGNERDAT H. WONG 62885 6-30-22 (FACING STREET) FOR SOUTH ELEVATION TYPICAL FOR ALL WINDOWS NOTE: TYPICAL FOR ALL WINDOWS FACING NORTH, EASR AND WEST ELEVATION 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD AND A.D.U ox4' H CBWCONC DRIVEWAY CONC SIDEWALKD/AD/A6' H WOOD FENCE (E) 5' H CBW (E) 5' H CBW (E) 4' H CBW (E) 4' H CBW DATE SCALE DRAWN JOB SHEET OF SHEETSPROJECT TITLE & LOCATION:L-1 AS SHOWN REVISIONS BY DESIGNEREFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN. ORDINANCE (ROSEMEAD MUNICIPAL CODE CHAPTER 13.08) AND APPLIED THEM FOR THE I HAVE COMPLIED WITH THE CRITERIA OF THE CITY OF ROSEMEAD WATER EFFICIENT LANDSCAPE SCALE: 1/8 " = 1'- 0"NORTHPLANTING PLAN NOTES: MULCH SPECIFICATIONS: MULCH NOTE: FOR GROUND COVER PLANTS AS PER 153.536 C. 1. MULCH MUST BE CONFINED TO AREAS UNDERNEATH SHRUBS AND TREES AND IS NOT A SUBSTITUTE RESIDUES HARMFUL TO PLANT OR ANIMAL LIFE. THE SPECIFIED PARTICLE SIZE, SALTS,PAINT, PETROLEUM, PESTICIDES OR OTHER CHEMICAL GLASS,PLASTIC, METALS, CLODS, WEEDS WEED SEEDS, COARSE OBJECTS, STICKS LARGER THAN MULCH MUST NOT CONTAIN MORE THAN 0.1 PERCENT OF DELETERIOUS MATERIALS SUCH AS ROCK, HAVE LENGTHS FROM 2 TO8 INCHES, WITH A WIDTH AND THICKNESS FROM 1/8 TO 1-1/2 INCHES. TREES WITH A HIGH LENGTH-TO-WIDTH RATIO. A MINIMUM OF 95 PERCENT OF THE STRANDS MUST SHREDDED BARK MULCH MUST A BLEND OF LOOSE, THIN WOOD OR BARK PIECES DERIVED FROM SHREDDED BARK MULCH LEGEND: (N) CONCRETE (N) LAWN (N) PERMEABLE PAVERS TOTAL LANDSCAPE AREA (LA) TOTAL TURF AREA TO CONFORM TO SOIL ANALYSIS REPORT RECOMMENDATIONS. BIDDING PURPOSES ONLY. CONTRACTOR SHALL ADJUST ACTUAL AMENDMENTS AND BACKFILL MIXES TO GRADING WORK. ANY SOIL AMENDMENTS AND FERTILIZER LISTED IN THE SPECIFICATIONS ARE FOR FINAL GRADING AND BEFORE PLANTING, AS THE SURFACE SOIL IN LANDSCAPE AREAS MAY CHANGE DUE REPORT AND SPECIFIC AMENDMENT RECOMMENDATIONS. SOIL TESTING SHALL BE DONE FOLLOWING 2. CONTRACTOR SHALL OBTAIN SOIL TEST FOR AGRICULTURAL SUITABILITY INCLUDING A SOILS ANALYSIS 6. SEE ARCHITECTURE AND CIVIL PLANS FOR EXACTLY DIMENSION AND SPECIFICATION. DISPENSER EVENLY THROUGHOUT ALL PLANTING AREAS EXCEPT TURF AREA. 5. SHREDDED WOOD CHIPS 1"-3" LENGTH, 3/8"-5/8" DIAMETER, 3" MIN THICK 4. ALL LANDSCAPING SHALL BE MAINTAINED IN A NEAT AND HEALTHY CONDITION. 3. ALL PAVEING AREAS SHALL BE KEPT CLEAN AND FREE OF DUST,MUD OR TRASH. DURING THE COURSE OF CONSTRUCTION. 2. EXISTING TREE INDICATE TO BE REMAINED SHALL BE PRESERVED AND PROTECTED 1. ROOT BARRIERS SHALL BE PROVIDED FOR ALL TREES WITHIN 5' OF HARDSCAPE. SOIL TEST REQUIREMENT DIVIDER (TYP) SEE DETAILS 1 1" X 4" BEND- A - BOARD TYP4 PORCH (N) BLOCKWALL 3 4 5 6 7 8 9 BOTANICAL NAME COMMON NAME TYPE SIZE SHRUB SHRUB 1 GAL 1 GAL ITEM NO.SYMBOL QUANTITY "SUNSET" CISTUS X PULVERULENTUS MAGENTA ROCKROSE SHRUB SHRUBFRENCH LAVENDER 10 SHRUB SHRUB 1 GAL 2' X 3' 3' X 3' 2' X 2' WATER NEED FROM WULCOLS LAVANDULA DENTATA LOW LOW 3' X 2'LOW 1 GAL 1 LOW 9 LOW 1 GAL 1 GAL 7 7 4 6 6 HEIGHT X SPREAD MATURE SIZE ROSA x "NOAMEL"APPLEBLOSSOM ROSE CALLISTEMON "LITTLE JOHN" BOTLEBRUSH LITTLE JOHN DWARF SALVIA FARINACEA CATHEDRAL CATHEDRAL SALVIA 1' 6" X 1'6" "WINKY BLUE & WHITE" AQUILEGIA CAERULEA COLUMBINE WINKY BLUE & WHITE 1'6" X 1'0" TALL FISCUE SODMARTHON II LAWN SOD MODERATE 860 S.F. PLANTING LEGEND PL PL PL PL CONC. WALKWAY TYP7 TYP2 1TYP TYP6 TYP3 3,447 S.F.DESIGNER5 TYP PERMEABLE PAVER (TYP) TREE 24"CERCIS OCCIDENTALIS CALIFORNIA REDBUD 20' - 30'LOW1 24"TREESWEET BAY 30' - 40'LOWLAURUS NOBILIS 2 YES YES YES YES YES YES YES YES DROUGHT TOLERANT NATIVE AND/OR CALIFORNIA 53.00'53.00'150.49' 150.50'CL25'25'STWASOLA2-STORY SFD 7731 WASOLA STREET 7731 WASOLA STREET ROSEMEAD CA 91770NEW SFD No. Exp. CIVILREGISTERED PROFESSION AL E N GI NEERST AT E OF CALIFORNIA DAT H. WONG 62885 6-30-22 dathwong@yahoo.com626-627-53935635 ANGELUS AVE. SAN GABRIEL CA 91776DAT H. WONG2 TYP9 2245 S.F. MG W/H W/H