ADDENDUM 3, ROSEMEAD, BOLLARD INSTALLATION AT ENCINITA AND PITKIN, 01-10-22
CITY OF ROSEMEAD
CALIFORNIA
ADDENDUM #3
CONTRACT DOCUMENTS
SPECIFICATIONS AND STANDARD DRAWINGS
FOR
BOLLARD INSTALLATION AT ENCINITAS AND PITKIN
PROJECT No. 24012
FISCAL YEAR 2021-2022
Date Issued: January 10, 2022
Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 1 of 4
Addendum 3, Page 1 of 1
Addendum for: Bollard Installation at Encinitas and Pitkin, Project No: 24012
Addendum No.: 3
Addendum Date: January 10, 2022
Issued by: City of Rosemead
Reminder 1: Please sign Addenda Acknowledgement on page CBF-3 of Bid Package Section Titled
“Contract Bid Forms”. Entire Section “Contract Bid Forms” shall be submitted as
Contractor’s Bid.
Addendum 3 revises the bid opening to January 13, 2022, 1 pm.
Due to the COVID-19 pandemic, the bids will be publicly opened via Zoom 30 minutes after the
bid deadline. Please see below Zoom access information for the bid opening:
Join Zoom Meeting
https://us02web.zoom.us/j/82341495553?pwd=TStDOHl2Nm8yc1NnT3RZU3FhWFNXdz09
Meeting ID: 823 4149 5553
Passcode: 864116
One tap mobile
+16699009128,,82341495553#,,,,*864116# US (San Jose)
+13462487799,,82341495553#,,,,*864116# US (Houston)
Dial by your location
+1 669 900 9128 US (San Jose)
+1 346 248 7799 US (Houston)
+1 253 215 8782 US (Tacoma)
+1 646 558 8656 US (New York)
+1 301 715 8592 US (Washington DC)
+1 312 626 6799 US (Chicago)
Meeting ID: 823 4149 5553
Passcode: 864116
Find your local number: https://us02web.zoom.us/u/kchVDVNlkS
This addendum also provides a revision to Attachment A - Safety Steel Bollard Specifications to be added
to Technical Provisions. The revision modifies the bollard from 16 gauge steel to Schedule 40 steel.
Attachments
Attachment A - Safety Steel Bollard Specifications
Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 2 of 4
Attachment A - Safety Steel Bollard Specifications
Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 3 of 4
Safety Steel Bollard Specifications (not to scale)
Safety steel bollard shall comply with the following requirement:
1.Constructed of Schedule 40 steel, 6” in diameter and filled with minimum 3,000 PSI
concrete, with rounded top
2.Spaced at 4’ on center between posts
3.Set at 3 feet deep in a concrete footing 15” diameter
4.Top of post shall be 4 feet above ground
5.Bollard shall be powder coated “OSHA” safety Yellow
Dirt
6” bollard to be filled with min
3,000 PSI concrete, rounded top
4 ft
3 ft
Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 4 of 4