ADDENDUM 3, ROSEMEAD, BOLLARD INSTALLATION AT ENCINITA AND PITKIN, 01-10-22 CITY OF ROSEMEAD CALIFORNIA ADDENDUM #3 CONTRACT DOCUMENTS SPECIFICATIONS AND STANDARD DRAWINGS FOR BOLLARD INSTALLATION AT ENCINITAS AND PITKIN PROJECT No. 24012 FISCAL YEAR 2021-2022 Date Issued: January 10, 2022 Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 1 of 4 Addendum 3, Page 1 of 1 Addendum for: Bollard Installation at Encinitas and Pitkin, Project No: 24012 Addendum No.: 3 Addendum Date: January 10, 2022 Issued by: City of Rosemead Reminder 1: Please sign Addenda Acknowledgement on page CBF-3 of Bid Package Section Titled “Contract Bid Forms”. Entire Section “Contract Bid Forms” shall be submitted as Contractor’s Bid. Addendum 3 revises the bid opening to January 13, 2022, 1 pm. Due to the COVID-19 pandemic, the bids will be publicly opened via Zoom 30 minutes after the bid deadline. Please see below Zoom access information for the bid opening: Join Zoom Meeting https://us02web.zoom.us/j/82341495553?pwd=TStDOHl2Nm8yc1NnT3RZU3FhWFNXdz09 Meeting ID: 823 4149 5553 Passcode: 864116 One tap mobile +16699009128,,82341495553#,,,,*864116# US (San Jose) +13462487799,,82341495553#,,,,*864116# US (Houston) Dial by your location +1 669 900 9128 US (San Jose) +1 346 248 7799 US (Houston) +1 253 215 8782 US (Tacoma) +1 646 558 8656 US (New York) +1 301 715 8592 US (Washington DC) +1 312 626 6799 US (Chicago) Meeting ID: 823 4149 5553 Passcode: 864116 Find your local number: https://us02web.zoom.us/u/kchVDVNlkS This addendum also provides a revision to Attachment A - Safety Steel Bollard Specifications to be added to Technical Provisions. The revision modifies the bollard from 16 gauge steel to Schedule 40 steel. Attachments Attachment A - Safety Steel Bollard Specifications Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 2 of 4 Attachment A - Safety Steel Bollard Specifications Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 3 of 4 Safety Steel Bollard Specifications (not to scale) Safety steel bollard shall comply with the following requirement: 1.Constructed of Schedule 40 steel, 6” in diameter and filled with minimum 3,000 PSI concrete, with rounded top 2.Spaced at 4’ on center between posts 3.Set at 3 feet deep in a concrete footing 15” diameter 4.Top of post shall be 4 feet above ground 5.Bollard shall be powder coated “OSHA” safety Yellow Dirt 6” bollard to be filled with min 3,000 PSI concrete, rounded top 4 ft 3 ft Addendum 3, City of Rosemead, Bollard Installation at Encinitas and Pitkin Document Control Page 4 of 4