Loading...
PC - Item 3A - Exhibit B - CUP 22-01 Site Plan and Floor Plan36 X 24 Of SheetsPROJECT:OWNER:ARIETY L.J & ASSOCIATE DESIGN V Revisions By 6710 N. ROSEMEAD BL. SAN GABRIEL CA 91775 TEL: 626-833-0035 Date 4/8/2022 Scale Checked 1/16"=1'-0" LIFU JUDrawn A - 1SITE PLANENGINEER:LAI C LA2111 SAN GABRIEL BLVD #FROSEMEAD, CA 91770TEL: 626-500-90534. RESTROOM WALLS WITHIN 2-FT. OF THE FRONT AND SIDES OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD NON-ABSORBENT SURFACE SUCH AS CONCRETE, TILE OR OTHER APPROVED MATERIAL AND EXTEND UPWARD ONTO THE WALLS AT LEAST SIX(6) INCHES. 3. RESTROOM FLOORS SHALL HAVE A SMOOTH, HARD NON-ABSORBENT SURFACE SUCH AS CONCRETE, TILE OR OTHER APPROVED MATERIAL THE LOCAL CODES, LAWS, AND WORK SHALL COMPLY WITH THE CODES. 1. ALL WORK, INCLUDING MATERIALS AND WORKMANSHIP, SHALL CONFORM TO TO A HEIGHT OF 4-FT. THE 10" LOWER PORTION OF WALL TO BE SMOOTH & PLANE SURFACE 7. POST SIGN PER CBC WHEN THE BUILDING IS OCCUPIED" "THIS DOOR TO REMAIN UNLOCKED (RAISED CHARACTERS AND BRAILLE) EXIT SIGNS ARE REQUIRED ON THE WALL 8. TACTILE EXIT SIGNS: TACTILE ADJACENT TO THE LATCH SIDE AT 48" - 60" TO THE BASE LINE OF TEXT. EXTERIOR LANDING, WITH VERTICAL SURFACES NOT MORE THAN 1/4 INCHES IN 9. THRESHOLD HEIGHT TO NOT EXCEED 1/2 INCHES IN HEIGHT ABOVE FLOOR AND HEIGHT. EFFORT WITH NO TWISTING OR GRASPING OF HARDWARE REQUIRED, AND WITH 10. DOOR TO HAVE LEVER TYPE HARDWARE OPERABLE WITH ONE HAND AND SINGLE NO MORE THAN 5 POUNDS EFFORT. ELONGATED OPEN-FRONT TYPE. 5. WATER CLOSEDS MUST ELONGATED BOWL TYPE. WATER CLOSET SEATS MUST BE a) THE 2019 EDITION OF THE CALIFORNIA BUILDING CODE (CBC). b) THE 2019 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC). c) THE 2019 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC). d) THE 2019 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC). e) THE 2019 EDITION OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE. 11. A PRIMARY ENTRANCE TO THE BUILDING AND THE PRIMARY PATH OF TRAVEL TO THE ALTERED AREA MUST BE SHOWN TO COMPLY WITH ALL ACCESSIBILITY FEATURES. POINT FROM THE TOP & AT 1/3 POINT FROM THE BOTTOM OF THE W/H SPILL HOT WATER AWAY FROM EXTERIOR WALL 6 INCH TO SOIL. 6. WATER HEATER SHALL BE STRAPPED FOR SEISMIC LATERAL LOAD AT 1/3 RESPECTIVELY VENT GOES THROUGH THE ROOF TOP TO OUTSIDE RELEASE 2. CURRENT CODES f) THE 2019 EDITION OF THE CALIFORNIA ENERGY STANDARDS. ACCESSIBILITY DOOR DETAILS PARKING ONLY VAN ACCESSIBLE MINIMUM FINE $250 UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE TOWED VEHICLES MAY BE RECLAIMED AT OR BY TELEPHONING NOTE: THE ADDITIONAL "TOW-AWAY" LETTERS SHALL HAVE A MINIMUM HEIGHT OF 1" TOWING COMPANY'S NAME AND TELEPHONE NUMBERS MUST BE PROVIDED ON SIGN SIGN SHALL BE 17" MIN. X 22" MIN. 17" MIN.22" MIN.NOTE: SIGNS LOCATED W/IN A.F.F. OR ABOVE GROUND SURFACE. SIGNS MAY ALSO BE PERMANENTLY ACCESSIBLE ROUTE SHALL BE 80" MIN.60" MIN.POSTED ON A WALL AT THE INTERIOR END OF THE PARKING SPACE REFLECTORIZED WITH MINIMUM AREA OF 70 SQ.IN. GROUND SURFACE FINISH WHERE APPLIES THIS PROJECT'S ALL DOORS MUST BE USED THE LEVER TYPE OF HARDWARE 5 LB. MAX. EFFORT TO OPERATE INTERIOR DOORS. 5 LB. MAX. EFFORT TO OPERATE EXTERIOR DOORS. 15 LB. MAX. EFFORT TO OPERATE FIRE DOORS. 3'-0" MIN.6 - 8" MIN.INSTALL OPERATING HARDWARE 34" TO 44" ABOVE FLOOR ACCESSIBLE DOOR OPERATING HARDWARE THRESHOLDS @DOORWAYS PUSH/PULLS LEVERS PANIC BARS SMOOTH SURFACES @DOORS MINIMUM CLEARANCES @DOORS 10" HIGH SMOOTH SURFACE SHALL BE PROVIDED ON THE "PUSH" SIDE OF THE DOOR PUSH HINGED DOOR 32" MIN. 32" 32" ALLOW CLEARANCE FOR PULL HANDLES ON DOOR FOLDING DOOR SLIDING DOOR 24"MAX.MIN. MIN. DOOR FLOOR 2 1 1/2" max. @ 1:2 SLOPE 1/4" max. PICTORIAL SIGNAGE (b) display conditions (a) symbol proportions These diagrams illustrate the specific requirements of these regulations and are intended only as an aid for building design and construction 7 5 4 EXITTACTILE EXIT SIGN6 48" - 60"TO BASELINE OF TEXTGROUND SURFACE FINISH BUSINESS NAME: JOB ADDRESS: LAI C LA 2111 SAN GABRIEL BLVD #F ROSEMEAD, CA 91770 TYPE OF CONSTRUCTION: NUMBER OF STORY: TYP OF BUSINESS: FLOOR AREA:783 S.F. V-B 1 OCCUPANCY TYPE:B FIRE SPRINKLERED:NO MASSAGE SERVICE a) THE 2019 EDITION OF THE CALIFORNIA BUILDING CODE (CBC). b) THE 2019 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC). c) THE 2019 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC). d) THE 2019 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC). f) THE 2019 EDITION OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE. g) THE 2019 EDITION OF THE CALIFORNIA ENERGY STANDARDS. e) THE 2019 EDITION OF THE CALIFORNIA FIRE CODE (CFC). AND LOCAL JURISDICTION AMENDMENTS. THE NEW PARTITION WALLS FOR ADDITIONAL MASSAGE ROOMS. OCCUPANCY LOAD:783 S.F. 100 S.F.= 8 OCC. 8 H/C PARKING DETAIL NO PARKING 9'-0" MIN. EDGE OF GUTTER (CURB IF NO GUTTER) WHEEL STOP 45O 4" BLUE LINE BORDER 4" HATCHED DIAGONAL LINES AT 36" MAX. ON CENTER PAINTED A CONTRASTING COLOR WITH THE PARKING SURFACE WTITE ON AC BLUE ON CONCRETE 4" BLUE LINE ACCESS AISLE: MINIMUM WIDTH IS 5' FOR A REGULAR ACCESSIBLE PARKING STALL 8' FOR A VAN ACCESSIBLE PARKING STALL 4'-0" MIN. 1.5 %2 %2 %CONTIGUOUS SIDEWALK 10% MAX. 10% MAX.8.33%MAX.3'-0" UNOBSTRUCTED AREA 18'-0" MIN.4" BLUE LINEISA SYMBOL TYPICAL 9'-0" MIN. CL CL CURB RAMP 4'-0"MIN.ACCESSIBILITY PARKING SIGN 0 #2111 A #2111 C #2111 D #2111 E #2111 F #2111 G #2111 H #2111 I #2111 J #2111 B #2101 #2121 #2123 ELECTRICAL BOX TrashTr a s h 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26.27.28.29.30.31. 40.41.42.43.44.45.46. 53.52.51.50.49.48.47. (E) 70 SQ. INCH ACCESSIBILITY SIGN PER CODE TYP. W/VAN ACCESSIBLE SIGN W/MINIMUM FINE $250 _7 8_(E) ACCESSIBLE PARKING TYP. CHANGE OF USE "FROM A REAL ESTATE TO A MASSAGE PARLOR".CEILINGDRY WALL CEILING ROOMSSEMI GLOSS ENAMEL PAINT SEE NOTE 1 WASHABLE SMOOTH "T" BAR CEILING PANEL "USG" GYPSUM, WHITE VINYL 2x4 OR 2x2 ACOUSTIC CLG PANEL CERAMIC TILE (SMOOTH, NON-SLIP) HARD WOOD FLOOR VINYL TILE 12"x12" SHEET VINYL FLOOR (CONTINUE) EXISTING CONC. FL. METAL FLOOR (FOR WALK-IN FREEZER)WALLSEMI GLOSS ENAMEL PAINT SEE NOTE #1 WASHABLE SMOOTH CEREMIC TILE TO CEILING FLOORQUARRY TILE (SMOOTH, NON-SLIP) "USA" DRY WALL (GYPSUM BD.) WITH PAINT COVED BASEQUARRY TILE 6"H.(SMOOTH) "USA" CERAMIC TILE 6"H. (CONTINUE)1) wall and ceillings all areas shall be durable, smooth, and nonabsorbent, with a light colored (light colored is defined as having a light reflectance value of 70% or greater) easily cleanable, washable finish.NOTEFINISH SCHEDULE FACIAL RMRESTROOM.WAITING RMRECEPTIONCEREMIC TILE 4'H (SHOWER RM TILE 80"H)STORAGE RMEMPLOYEE/LAUN. RMMASSAGE RMHALLWAY38.37.36.35.34.33.32.39. ZONING:C-3 GENERAL PLAN DESIGNATION:MIXED USE: INDUSTRIAL/COMMERCIAL PROPOSED TOTAL NUMBER OF MASSAGE ROOMS: 3 b. NO WINDOWS THAT FRONT A PUBLIC STREET, HIGHWAY, OR PARKING AREA SHALL BLOCK VISIBILITY INTO THE INTERIOR RECEPTION AND WAITING AREAS THOUGH THE USE CURTAIN, CLOSED BLINDS, TINTS, OR ANY OTHER MATERIAL TINTED OR "ONE-WAY" GLASS IN ANY ROOM OR OFFICE. a. NO MASSAGE ESTABILISHMENT OR ACCESSORY USE LOCATIONS EMPOLYING MASSAGE THERAPISTS SHALL BE EQUIPPED WITH THAT OBSTRUCTS OR DARKENS THE VIEW INTO PREMISES OR BY SIGNS THAT THAT COVER MORE THAN FIFTEEN (15) PERCENT OF ANY WINDOWPANE. THE INTERIOR OF BUSINESS SHALL BE PLAINLY VISIBLE FROM THE EXTERIOR OF THE BUSINESS BY PASSING VEHICLES AND PEDESTRIANS. MUNICIPAL CODES. c. THE APPLICANT SHALL COMPLY WITH ALL THE REQUIREMENTS REGARDING MASSAGE ESTABLISHMENT PURSUANT TO CHAPTER 5.24 OF THE ROSEMEAD THE CALIFORNIA MASSAGE THERAPY COUNCIL (CAMTC) CREATED BY THE d. NO PERSON MAY ENGAGE IN CONDUCT, CARRY ON, OR PERFORM MASSAGE THERAPY UNLESS SUCH PERSON HAS A VAILD AND ACTIVE CERTIFICATE FROM CALIFORNIA BUSINESS AND PROFESSION CODE 4600. e. IT IS RECOMMENDED THAT THE ESTABILSHMENT MAINTAIN A 24-HOUR VIDEO SURVEILLANCE RECORDING SYSTEM TO INCLUDE COVERAGE OF THE FOLLOWING AREA: a. ALL PATRON AND EMPLOYEE ARRIVALS AND DEPARTURES b. IMMEDIATE AND ADJOINING PARKING AREA c. ENTIRE EXTERIOR PERIMETER d. ANY OFFICE AND CASHIER AREA e. GENERAL FLOOR AREA f. THE VIDEO SURVEILLANCE MUST BESTORED FOR MINIMUM OF 30 DAYS AND BE MADE AVAILABLE TO LAW ENFORCEMENT AND CODE ENFORCEMENT UPON REQUEST. g. THE PARKING LOT AND EXTERIOR OF THE BUSINESS MUST MAINTAIN GOOD LIGHTING DURING THE HOUES OF DARKNESS. h. THE PROPERTY SHALL BE SUBJECT TO INSPECTIONS BY CODE ENFORCEMENT AND LAW ENFORCEMENT DURING ALL BUSINESS HOURS. 36 X 24 Of SheetsPROJECT:OWNER:ARIETY L.J & ASSOCIATE DESIGN V Revisions By 6710 N. ROSEMEAD BL. SAN GABRIEL CA 91775 TEL: 626-833-0035 Date 4/8/2022 Scale Checked 1/4"=1'-0" LIFU JUDrawn A - 2FLOOR PLANENGINEER:LAI C LA2111 SAN GABRIEL BLVD #FROSEMEAD, CA 91770TEL: 626-500-9053SC : 1/4"=1'-0" NO QUA 1 EQUIPMENT SCHEDULE 3 EMPLOYEE LOCKERS DESCRIPTION ALL EQUIPMENTS MEET NSF STANDARS 2 1 DOCUMENT CABINET ( LOCATED ON 6" H LEGS ) 3 3 4 MASSAGE TABLE 5 6 1 RECEPTION COUNTER 34"H 1 EXISTING WATER HEATER EXIST'G WALL NEW WALL 2x4 STUD @ 16"O.C. .')'0& 1 PICTORIAL SIGNAGE GRADE 2 BRAILLE 58"- 60" TO C OF48" - 60"TO BASELINE OFTEXTSYMBOLLRESTROOM12"RESTROOMS (ALL GENDER) 12"24"min.min. 36" min. GRAB BAR 33" min.min.36" min.19"33" min. TO 36" max.min.48" _ A 7"-9" 12"42" min. max.GRAB BAR 54" min.17"-19"2 FRONT & SIDE ELEVATION A NOMINAL DIAMETER 1-1/4" min. TO 2" max. WALL 1-1/2" 17" min. FLUSH HANDLE SIDE 24" min. GRAB BAR SECTION ALL DISPENSERS +40" MAX TO HIGHEST OPERABLE PART GRAB BAR 18" max.36" max.60"min. 1 _ W H 5 COUNTER 34"HPORTABLE4 3 3 3 6 1 2 CLEAN LINEN CABINET 6 6 42" min._ 2 GRAB BAR 7'-5"2'-8"3'-0" 19'-5"11'-0"11'-0"8'-4"7'-0"12'-10"7'-8" 7'-8"38'-4"(E) 6'x4' WINDOW3'-8" EXISTING DOOR 36" W 6'-8"H IS SMOOTH, & PLANE SURFACE THE DOOR OF LOWER 10" 43"H ABOVE THE FLOOR HARDWARE MOUNTED THAN 1/2"ABOVE THE FLOOR THRESHOLD NO HIGHER ENTRANCE SIGN PER 2019 CBC 5 A-1 ON THE LATCH SIDE OF DISABLED ACCESS : W/ "TACTILE EXIT SIGN" EXIT DOOR" 6 A-1 EXIT "EXIT" SIGN BACK-UP POWER 90 MINUTES MIN. TYP. SIGN ABOVE THE DOOR. PROVIDE ILLUMINATED 4 A-1 DOOR DETAILS ACCESSIBILITY4A-13 KNEE & TOE SPACE FOR SINK AND MIRROR4 40" MAX.MIRROR LOCATION9" MIN.27" MIN.29" MIN.34" MIN.TOE CLEARANCE 6" MAX. 17" MIN. 8" MAX. KNEECLEARANCE If a min. 9" height of toe clearance is provided, a max. of 6" of the 48" of clear floor space required at the fixture may extend into the toe space.18" MIN.17" MIN. CLEAR FLOOR SPACE30" MIN.48" MIN. 19" MAX. CL 3_1'-6"60"min. 7 1 WAITING ROOM SOFA 7'-5" 8 3 LOCKER OF PATRON 8 8 860"m in . 1/2" MAX. BEVELED 15"max.GRAB BAR 24" min.F.D.max. 16"max. 2'-0"7'-0"6'-4" 36" min. GRAB BAR 72'-8"15'-6"2'-4"5'-5" SHOWER ROOM DETAIL 27" MAX 19" MAX 27" MAX CL 18"39" TO 41"33" TO 36"48" MAX TO TOPCONTROL AREA OF MOUNTING BRACKET8'-0"FOLDING SEATCLCL BACK/CONTROL WALL CONTROLS WITHIN 18"-24" FROM HANDHELD SHOWERHEAD SEAT, CONTROLS 40"AFF REAR WALL @48" AFF WITH DIVERTER & SHOWER 60" HOSE IS RELOCATED TO THE 1. SHOWERS AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH MIXING VALVES. 2. EACH SHOWERHEAD SHALL NOT EXCEED A WATER FLOW OF 2.5 GPM. 3. EACH FAUCET SHALL NOT EXCEED A WATER FLOW OF 2.2 GPM. 4. LAVATORY FAUCETS IN RESTROOMS SHALL BE THE SELF CLOSING TYPE. 5. PROVIDE EXPANSION TANK OR OTHER APPROVED METHOD OF RELIEVING PRESSURE. 5 _ 5 12"max. 48" MIN.5' MIN.