Loading...
CC - Item 2A - Attachment D - Comment Letter dated August 7, 2025Attachment D Comment Letter Dated August 7, 2025 MAYOR: MARGARET CLARK MAYOR PRO TEM: SANDRA ARMENTA COUNCIL MEMBERS SEAN DANG POLLY Low STEVEN LY August 7, 2025 City of Wgsemead 8838 E. VALLEY BOULEVARD ROSEMEAD, CALIFORNIA 91770 TELEPHONE (626) 569-2100 FAX (626) 569-2303 Trumark Homes 450 Newport Center Drive, Suite 300 Newport Beach, CA 92660 Attn: Phil Wagner SUBJECT: PRE -APPLICATION 25-02 8001 GARVEY AVENUE Dear Applicant: Thank you for your interest in the City of Rosemead. On July 9, 2025, the Planning Division received your Pre -Application requesting to construct a horizontal commercial/residential mixed -use development. The following comments and conditions are based on the preliminary plans that were submitted. Staff understands the plans are preliminary for the purpose of the pre -application review. However, in order for City staff to complete a thorough review of the project, the architectural plans require more detailed information. Please also be aware that additional issues could arise as more information is received. Application Requirements The following applications and fees for the project will be required. Additional applications may be required once complete sets of plans have been submitted. 1. Garvey Avenue Specific Plan Review - $ 975 per review 2. Tentative Tract Map - $1,602 + $100/lot 3. Conditional Use Permit for the proposed hotel use - $ 1,635 4. Environmental Review — A consistency evaluation is required to determine if the project can be exempt pursuant to California Environmental Quality Act (CEQA) Section 15183. 5. Third -Party Geological/Geotechnical Review — In progress 6. Publication - $557 7. LA County Recording Fee — $ 75 8. Development Impact Fees — On June 9, 2015, the City Council adopted Ordinance 949, to establish Development Impact Fees. The fee for developments in Mixed Use Zones are: • Multi -Family: $5,126 (per dwelling unit) • Retail: $1,242 (1,000 sq. ft) • Office: $1,812 (1,000 sq. ft) Phasing of Project 9. Comment: The City understands the agreement between the City and the expectations and deliverables over established. Project Summary project will be phased. A performance applicant outlining specific performance a defined construction period may be 10.Comment: Please list all associated Assessor Parcel Numbers (APNs). 11. Per Rosemead Municipal Code Section 17.04.050 - Definitions —General, "Floor Area Ratio (FAR)" means the total square -footage of floor area on a lot divided by the gross area of the lot. Such calculation shall include only those structures intended for permanent habitation. For all subdivisions and unimproved vacant lots FAR calculations shall use the net area of the proposed lot. Comment: Since the subject site is an unimproved vacant lot, please calculate the FAR utilizing the net area for the entire site. 12. Garvey Avenue Specific Plan Table 3.4- Floor -Area Land Use Mix: The allowable land use mix is 65% residential and 35% nonresidential. However, with the incorporation of the "Nonresidential Component of Mixed -Use Development Sites" community benefit incentive, the land use mix may be increased to 70% residential and 30% nonresidential. In addition, the Community Development Director may approve minor modifications to the Specific Plan without a Specific Plan Amendment. Comment: Please specify if the project is proposing to utilize the "Nonresidential Component of Mixed -Use Development Sites" community benefit incentive and provide calculations to ensure the requirements are met. 13. Comment: Please provide the name, address, and telephone number of all service providers, including water sewer, school(s), utility companies, etc. 2 14.Comment: Indicate the type of building construction and occupancy (per Uniform Building Code). Site Plan 15.Comment: Per Garvey Avenue Specific Plan Table 3.4, the setback requirements are as listed below: a. Front: None - Met b. Side: i. East: 10 feet — Not Met (northeast portion is 8 feet) ii. West: None,10 feet, and 10 feet with Variable Height Requirements — Indicate the setback from the proposed parking structure to the west property line. In addition, please revise the plans to indicate that the variable height requirement applies to northwest portion of the lot. c. Rear: 25 feet and Variable Height Requirements - Met 16. Per Garvey Avenue Specific Plan Table 3.4, the minimum building placement on lot frontage is 60%. Comment: Please depict on the plans that this requirement is met. 17. Comment: Per Rosemead Municipal Code Section 17.28.030(D), the project shall comply with the Public Realm and Streetscape requirements listed below: a. Public Sidewalks. The following shall apply to public sidewalks: 1) The minimum building setback shall be twelve (12) feet as measured from the curb face, and shall be in the form of both existing right-of-way and a recorded pedestrian access and utility easement; 2) The minimum building setback area shall include a minimum seven - foot wide detached sidewalk (clear zone) and a minimum five-foot wide parkway (amenity zone) adjacent to all streets. The amenity zone shall be located between the curb face and the clear zone. The clear zone shall be located between the building and the amenity zone; 3) The sidewalk in the clear zone shall be constructed of concrete, comply with ADA accessibility standards and be subject to the review of the City Engineer; 4) The clear zone shall be unobstructed by any permanent or nonpermanent element for a minimum width of seven feet and a minimum height of eight feet; and 5) The amenity zone shall include street trees, landscaping, public signs, public art, street lighting, street furniture, and other pedestrian -oriented amenities, as appropriate. 3 b. Street Trees. 1) All species of mature oak trees shall be preserved or otherwise dealt with in accordance with Article 4, Chapter 17.104. 2) The removal of other mature trees shall be subject to the review and approval of the Urban Forester. 3) Mature street trees that are approved for removal by the Urban Forester shall be replaced with a minimum of three new mature box trees that have at least a 24-inch box and are the same species of the replaced mature street trees or a species approved by the Urban Forester. The City reserves the right to increase the number of trees if it deems necessary in order to compensate for mature tree loss. 4) The amenity zone shall be planted with street trees at an average spacing not greater than thirty (30) feet on center. c. Transit Stops. 1) Transit stops shall be designed as integral elements of a residential/commercial mixed -use development by collocating them with pedestrian -oriented amenities, such as pocket parks, courtyards, plazas, etc., whenever possible. 2) When an existing transit stop is located on a sidewalk adjacent to the location of a development, a shelter for transit patrons shall be constructed that: a) Incorporates architectural features of the development and is compatible with the development; and b) Includes a shelter, bench and lighting. d. Undergrounding of Utilities. 1) Utility lines to a development from the building to the property line, including, but not limited to, electric, communications, street lighting and cable television shall be placed underground. 2) Utility lines within the right -of way shall be placed underground to the maximum extent practicable. The requirements of this section may be waived by the Planning Commission upon recommendation from the City Engineer if it is determined that topographical, soil or any other conditions make such underground installations unreasonable or impractical. M Floor Plan 18. Per Rosemead Municipal Code Section 17.112.090, each required parking space in a residential garage shall be not less than ten (10) feet wide, seven feet high, and twenty (20) feet long and shall be in a garage. Not more than one tandem space shall be permitted within residential garages. Comment: Staff acknowledges that the garage dimensions are labeled, however, please depict the interior dimensions of all garages to ensure this requirement is met. Elevations/Design Nonresidential 19. Per Garvey Avenue Specific Plan Table 3.4, the maximum building height shall not exceed 75'. The maximum height is calculated to the top of roofline or roof structures including but not limited to elevator housing, stairways, tanks, ventilating fans, roof signs, etc.. An additional 5' beyond the height limit is allowed for unique architectural elements as determined by the Community Development Director. Comment: Please revise the plans to comply with this requirement and depict the height of the building from its highest point. 20. Per Garvey Avenue Specific Plan Section 3.4.5, fagade plane modulation is required. The wall plane of street -facing fagades shall be modulated a minimum of 18" perpendicular to the plane at least once every 60', as measured along the property line. Comment: Please indicate on the revised plans that this requirement is met. 21. Per Garvey Avenue Specific Plan Table 3.4, the minimum ground floor height for nonresidential developments on the first floor shall be 14 feet. Comment: The proposed hotel development does not appear to satisfy the minimum ground floor height requirement of 14 feet. Please revise the plans to comply with these requirements. 22. Per Garvey Avenue Specific Plan Table 3.4, the area of ground level wall area that must be glazed with clear glass display windows and entries are: • Nonresidential: 50% minimum • Residential: 40% minimum Comment: Please indicate on the plans that this requirement is met. Residential The design of the nonresidential component of the mixed -use project is well -executed and visually appealing. However, the residential component would benefit from additional design elements to enhance its overall quality and cohesiveness with the rest of the development. 23.Comment: To reduce the apparent bulk and massing of the proposed residential units from the side elevations, please incorporate additional articulation into the building design. This may include variations in wall planes, rooflines, materials, colors, or other architectural features that break up large, flat surfaces and enhance visual interest. 24. Comment: Please continue the stone veneer or siding along the side elevations for Plan 1, Plan 2, and Plan 3. Landscape/Open Space 25. Per Garvey Avenue Specific Plan Table 3.4, a minimum of 6% of the entire lot shall be landscaped. Comment: Please provide calculations for the landscape requirement. 26. Comment: Please depict the following types of open space clearly on the plans and color code it accordingly by utilizing a legend: • Landscaping • Usable Public Open Space (applies to the nonresidential portion of the mixed -use project) • Usable Private Common Open Space (applies to the residential portion of the mixed -use project - eight feet minimum in any direction) • Usable Private Open Space (applies to the residential portion of the mixed - use project — 75 square feet minimum, five feet in any direction) Refer to Garvey Avenue Specific Plan Section 3.4.11 for detailed requirements. For an example, please click on the following link: http://www3.cityofrosemead.org/WebLink/DocView.aspx?id=61350&dbid=1 &repo =Rosemead 27. Comment: All landscape and irrigation plans shall comply with the requirements found in Rosemead Municipal Code (RMC) Chapter 13.08 — Water Efficient Landscapes. A copy of the City's Guidelines for implementation of WELO is attached. N Parkin 28. Per Garvey Avenue Specific Plan Table 3.4 — Access Driveway Width: One-way driveways shall be 14 feet minimum and 20 feet maximum, while two-way driveways shall be 24 feet minimum and 30 feet maximum. Comment: Please indicate the width of all proposed access driveways 29. Per Garvey Avenue Specific Plan Table 3.4, parking provided for residential uses or the residential component of a mixed -use structure must be covered and secure. Guest parking may be uncovered. In addition, the private residential bicycle parking shall be separated and secured (be located in the same vicinity as the residential parking). Comment: Please indicate on the plans how the parking spaces for the residential component (includes guest parking) of the mixed -use project will be secured and separated from the commercial uses and depict the location of bicycle parking for both residential and nonresidential portion of the mixed -use project. 30. Per Garvey Avenue Specific Plan Section 3.4.10, on the same premise with every building, structure, or part thereof erected or occupied for goods display, wholesale or retail, hotel, restaurant, or other similar use involving the receipt or distribution of materials or merchandise via trucks or vans, a minimum of one off-street loading space for each 6,000 s.f. of building floor area dedicated to the retail, commercial, hotel, restaurant use is required for the standing, loading and unloading services in order to avoid interference with the public use of adjacent streets or alleys. Required loading space shall not be included within the required parking space adjacent to a building or structure. Comment: Indicate the location of the 21 required loading spaces and indicate how the spaces will accommodate for truck loading and off-loading. 31. Garvey Avenue Specific Plan Table 3. 4 — Development Standards sets the off- street parking requirements for mixed -use developments in the Garvey Avenue Specific Plan project area. Mixed -use developments shall provide the following off- street parking requirements for the residential component: Provide no less than one standard sized parking space and 0. 5 standard sized guest parking space. Comment: Staff acknowledges that the residential guest parking requirement has not been met. The proposed driveway spaces do not count towards any off-street parking requirements. However, since the EV off-street parking spaces are located in the residential portion of mixed -use project and will be secured, they can be counted towards the residential guest parking requirement. 32. Comment: Please label the following off-street parking spaces: commercial loading, residential parking, and residential guest parking. 7 33. Per Rosemead Municipal Code 17.112.090 (A)(2)(c), where a parking stall is located abutting a wall, column, or similar structure, the stall width shall be increased by two feet. Comment: Please indicate all columns and obstructions where off-street parking exists. In addition, some off-street parking spaces are located abutting a wall. Please label the two feet clearance for all off-street parking spaces that are affected by this requirement. 34. Comment: Please indicate that all parking will be double striped. Please refer to the diagram below for our requirements. MINIMUM PARKING DIMENSIONS 18' ADD 2' TO END STALL ABUTTING A BUILDING OR OTHER OBSTRUCTION. VN-IEEL-STOP ¢p (TYP.) ¢ U,,. U 3°DOUBLE STRIPE °O Q 0. WRH 6"CIENRA'JCE DETVvLCPI STRIP['o TYP.I O U Ic 16' 35. Per Garvey Avenue Specific Plan Section 3.4.9, on -site parking that is visible from streets and sidewalks or located along rear, side, or interior lot lines shall be buffered from the street, sidewalk, or lot line by a minimum 5' in-depth landscape buffer. Further, parking that is visible from Garvey Avenue shall be buffered from the street, sidewalk or lot line by a minimum 5' in-depth landscape buffer that includes a decorative wall no higher than 3' to screen the vehicles Comment: Please indicate the depth of all landscape buffers along Garvey Avenue, Strathmore Avenue, and Virgina Steet to ensure this requirement is met. Walls and Fences 36.Comment: Per Rosemead Municipal Code Section 17.68.040(A) and (E): A six-foot high solid masonry wall shall be constructed and maintained along any side or rear lot line adjacent to residentially zoned or used property, school or park. The wall shall be not less than three feet but not more than four feet in height where it is adjacent to a required residential front yard setback. 0 Walls shall have a decorative color and texture consistent with the architectural style and materials of the commercial or industrial development. Architectural and other treatment of the wall is required o Where new walls are erected in locations visible from a public right- of-way, the use of full dimension caps, pilasters, and changes in wall surfaces (staggering) shall be applied. o In locations where walls might invite vandalism or graffiti, landscaping should be provided along the walls. Lighting 37. Comment: Per Rosemead Municipal Code 17.88.020: Lighting standards. A. A photometric survey (lighting plan) may be required at the discretion of the Community Development Director for new lighting proposed in multifamily, commercial, industrial, institutional, and mixed -use developments. B. All developments shall have exterior lighting that provides adequate visibility at entrances, public sidewalks, open areas, and parking lots with a safe level of illumination at night. C. Exterior lighting shall be of low intensity and shielded so that light will not spill out onto surrounding properties or project above the horizontal plane. In residential/commercial mixed -use and commercial/industrial mixed -use development, the lighting for commercial uses shall be appropriately shielded so that it does not negatively impact the on -site residential units. D. Flashing, revolving, or intermittent exterior lighting visible from any property line or street shall be prohibited, except if approved in conjunction with a public art project or as an accessory feature on a temporary basis in conjunction with a special event permit. E. Lighting shall be integrated with landscaping wherever possible. Comment: Please note on the plans that all lighting will be of low intensity and shielded so that light will not spill out onto surrounding properties or project above the horizontal plane. In residential/commercial mixed -use and commercial/industrial mixed -use development, the lighting for commercial uses shall be appropriately shielded so that it does not negatively impact the on -site residential units. Trash and Loading Areas 38. Comment: Per Rosemead Municipal Code Section 17.28.030(D)(5), trash and refuse collection, and recycling areas shall comply with the following provisions in addition to the requirements set forth in Article 3, Chapter 17.32 (Accessory Structures): A a. All trash enclosures shall be fully enclosed with self -closing and self -latching doors, and each enclosure shall accommodate both trash and recycling bins. b. Trash enclosures shall be an integral part of the building design whenever possible. c. Trash enclosures shall be of the same architectural style as the development. d. Trash chutes are encouraged. However, chute access must be screened from public view, be fully contained within a "chute closet" that is accessible by a self- latching door, and have a safety hatch that is necessary to pull in order to dispose of trash. e. Loading areas shall be clearly designated. f. Loading areas shall be screened from public view to avoid negative noise, visual, and illumination impacts on the residential portion of the development and may be accomplished by the construction of six-foot high perimeter walls that are architecturally compatible with the primary structures and on -site landscaping. g. All screening walls shall be landscaped using vines, hedges, or other plant material necessary to provide a minimum fifty (50) percent coverage. h. Trash pick up and loading activities are permitted only during the hours of seven a.m. to seven p.m. 39.Comment: Please contact the City's trash purveyor (Republic Services) to ensure that onsite waste storage would be adequate. In addition, the placement of individual bins along Garvey Avenue, Strathmore Avenue, and Virgina Steet are prohibited. Mechanical Equipment 40. Per Rosemead Municipal Code Section 17.16.030(A)(9): Mechanical Equipment, Loading Zones, and Service Area Screening. a. Wall -mounted equipment shall be flush with the exterior building walls and painted to match the color of the exterior of the building and screened from the view of any public right-of-way. Window -mounted air conditioners or exterior -mounted fans shall be prohibited. b. Ground -mounted and pad -mounted mechanical or utility equipment and other such similar equipment shall be screened from view from all public rights -of -way and adjacent properties by architectural building features, fencing or landscaping. c. Rooftops should be designed in a way that acknowledges their visibility from other buildings and the street. Equipment shall be screened on all four sides from both the street and neighboring buildings using parapets or similar architectural features and from the top where visible from an adjacent building of greater height. 10 d. Service and loading zones where visible from public streets and views from neighboring buildings and properties shall be screened by the use of decorative walls and/or dense landscaping that will serve as both a visual and a noise barrier. Comment: Please indicate all mechanical equipment and loading areas on the plans and indicate how they will be screened from view. Miscellaneous 41.A master sign program shall be required for all proposed signage. 42. Per Garvey Avenue Specific Plan Section 3.3.4, a proforma analysis or market study is required for all mixed -use project applications. Housing Element Sites Inventory 43.The subject site is listed in our Housing Element Sites Inventory to provide 186 moderate -income and 53 above moderate -income units. Comment: Staff recommends the incorporation of 186 moderate -income and 53 above moderate -income units to assist with the City's allocated RHNA of 4,612 units. However, if the site is to be developed at a lower density, the following written findings must be made, and supported by substantial evidence in the record: • Remaining sites identified in the Housing Element are adequate to meet the jurisdiction's remaining RHNA for the planning period by income category. • The findings should include a quantification of the remaining unmet need for the jurisdiction's RHNA at each income level and the remaining capacity of sites identified in the Housing Element, to accommodate that need by income level. Per the memorandum released by the California Department of Housing and Community Development Housing (HCD) on Government Code Section 65863, a lower residential density sometimes results from a jurisdiction either approving a development with residential units less than what was assumed for the site or affordable to a different income category than the site was assumed to accommodate. Comments from Reviewing Agencies 44. Enclosed with this letter are copies of the comment letters from the following agencies: a. City of Rosemead - Public Works Department 11 b. City of Rosemead - Building and Safety Division Additional comments may follow as the City of Rosemead Planning Division receives more information. Please feel free to contact me at (626) 569-2144 or alao@cityofrosemead.org with any questions or concerns you may have. Sincerely, Annie Lao Senior Planner 12 E M B 5 ° City of Rosemead AV ** Memorandum N�OkroagTEo �959 To: ANNIE LAO, SENIOR PLANNER From: Romany Basilyous, P.E. City Engineer By: Sevan Petrossian, P.E. Associate Engineer Date: August 05, 2025 Subject: 8001 GARVEY AVENUE Project Summary: Pre -application submitted to propose mixed -use development located at 8001 Garvey Avenue. Total lot Area is 15.8 acre and total number of Residential units are 201. The commercial component of the mixed -use project includes a six -story, 187-room. Each unit includes a two -car garage and guest parking. 1. The following are Public Works conditions; by obtaining a permit, the applicant agrees at their sole expense to complete any requirements set by these conditions: A. Provide Grading/Drainage, Street Improvement and Sewer plans for the project. B. The second sheet of building plans, grading/Drainage plans and/or offsite improvement plans is to list all conditions of approval and to include a copy of the Planning Commission Decision letter. This information shall be incorporated into the plans prior to the first submittal for plan check. C. Submit a site Demolition Plan showing disposition of existing improvements, existing utilities, and all easements. D. A soil/geotechnical report prepared by a Geotechnical Engineer, licensed by the State of California, shall be submitted by the applicant for approval by the City. The soil/geotechnical report shall address any soil preparation, foundation design criteria and to identify any other hazards pertaining to seismic activity or drainage issues including Percolation test results. E. A complete hydrology and hydraulic study shall be prepared by a Civil Engineer registered in the State of California to the satisfaction of the City Engineer and the Los Angeles County Flood Control and Water Conservation District, prior to any plan approval. F. A storm drain system shall be designed to the satisfaction of the City Engineer and/or the Los Angeles County Flood Control District prior to building permit issuance. Adequate capacity and coverage shall be provided for drainage facilities to service upstream tributary drainage areas, where required. Verify the project for compliance with MS4 requirements. G. An Erosion Control Plan shall be submitted clearly detailing erosion control measures. These measures shall be implemented during construction. The erosion control plan shall conform to national Pollutant Discharge Elimination System (NPDES) standards and incorporate the appropriate Best Management Practices (BMP's) as specified in the Storm Water BMP Certification. H. Submit a stockpile plan showing the proposed location for stockpile for grading export materials, and the route of transport. I. Detailed drainage system information of the lot with careful attention to any flood hazard area shall be submitted. All drainage/runoff from the development shall be conveyed from the site to the natural drainage course. No on -site drainage shall be conveyed to adjacent parcels unless that is the natural drainage course. Provide an engineering cost estimate for all onsite and offsite improvements, signed and stamped by licensed engineer. K. Separate permit shall first be obtained from the City Public Works Department prior to placement of any construction materials or equipment in the public way. L. Construct proposed Driveway approaches to comply with current ADA bypass requirements per SPPWC, latest edition. M. The required street improvements shall include those portions of roadways contiguous to the subject property and includes remove and reconstruct damaged and/or off -grade curbs, gutters, ADA ramps, driveway approaches, and sidewalks. N. At least 4ft Dedication is required to provide ADA bypass sidewalk on north-west corner of the property adjacent to the Virginia st. around the Cul De Sac up to the Strathmore Avenue. O. Protect -in -place existing public properties including: bus stops, fire hydrants, trees, sidewalk, and other improvements adjacent to subject property. P. Rehabilitate existing AC street pavement along the property frontage to the centerline of the Garvey Ave, rehabilitation includes but are not limited to pavement markers, striping, and markings as directed by the City Engineer or his/her designee. You may pay an in -lieu fee equal to the estimated cost of street rehabilitation based on the Los Angeles County Land Development Division Bond Calculation Sheets before the issuance of building permits to the satisfaction of the City Engineer or designee. Q. The Owner shall execute and record a covenant agreement to maintain and hold the City harmless for all existing improvements in the public right-of-way. R. An encroachment permit shall be required for any construction to be done in the public right of way, easements, or on lands to be dedicated to the City of Rosemead upon completion of the improvements. The encroachment permit shall be obtained prior to the start of said work. The permit fees will be determined per the current adopted development fee schedule. S. Protect -in -place existing public properties including: bus stops, fire hydrants, trees, sidewalk, and other improvements adjacent to subject property. T. Remove and replace damaged and/or uplifted concrete sidewalk/curb & gutter within subject property's frontage. U. Close existing driveway approaches no longer in use and replace with sidewalk per SPPWC latest edition. V. Applicant to verify if existing curb ramp on the corner of Garvey Ave. and Strathmore Ave. is ADA compliant, if not, it is to be replaced with an ADA compliant sidewalk ramp per SPPWC latest edition. If sidewalk ramp is deemed ADA compliant, applicant to re -install truncated domes only. W. Refresh curb painting (Red) fronting subject property. X. Provide Traffic Impact Analysis, Related impact and proposed design solution. determine the volume of traffic expected, traffic circulation issues, and if there is need to adjust the traffic signals. Y. Provide photometric plan and lighting poles foundation details for the project. SEWER Z. All existing laterals to be abandoned shall be capped at the public right of way to the satisfaction of the City Engineer and the Building Official of the City of Rosemead. UTILITIES AA. All power, telephone, cable television, and all utilities to the project and adjacent to the project shall be installed and relocated underground unless impracticable to the satisfaction of the City Engineer or designee. BB. Any utilities that conflict with the development shall be relocated at the developer's expense. Reviewed By: Department of Public Works/Engineering Devision Date : 08/04/2025 CITY OF ROSEMEAD BUILDING DIVISION RECOMMENDED CONDITIONS ADDRESS: 8001 Garvey Ave. APPLICATION NO.: PRE -APPLICATION 25-02 PROJECT DESCRIPTION: Proposed a new mixed -use development consisting of 1) a 6-story, 187- room hotel of 102,000 SF, 2) a 3-story commercial building of 26,810 SF, 3) a 3-tier parking structure of 214 parking spaces, 4) 201 residential dwelling units in 3 different types: 65 two-story single-family detached homes, 80 three-story duplex units, and 56 three-story townhomes, and 4) residential common use space including a dog park and a recreation center with a swimming pool. B 1. The second sheet of building plans is to list all conditions of approval and to include a copy of the Planning Commission Decision letter. This information shall be incorporated into the plans prior to the first submittal for plan check. B2. All construction plans shall comply with the codes in effect at the time of plan submittal to the Building Division. Please be advised that a new code cycle will take effect on January 1, 2026, which may impact design requirements if plans are submitted on or after that date. B3. School Developmental Fees shall be paid to School District prior to the issuance of the building permit. B4. Fees shall be paid to the County of Los Angeles Sanitation District prior to issuance of the building permit. B5. All project plan check applications shall indicate the address of 8001 Garvey Ave. for plan submittal purposes. An site map showing proposed building address assignments with unit numbers shall be submitted to the Building Official for approval and filed with the City prior to plan check submittal. B6. In accordance with paragraph 5538(b) of the California Business and Professions Code, plans are to be prepared and stamped by a licensed architect. B7. Structural calculations prepared under the direction of an architect, civil engineer or structural engineer shall be provided. B8. A geotechnical and soils investigation report is required, the duties of the soils engineer of record, as indicated on the first sheet of the approved plans, shall include the following: a) Observation of cleared areas and benches prepared to receive fill; b) Observation of the removal of all unsuitable soils and other materials; c) The approval of soils to be used as fill material; d) Inspection of compaction and placement of fill; e) The testing of compacted fills; and f) The inspection of review of drainage devices. Pagel U4 V2023 B9. The owner shall retain the soils engineer preparing the Preliminary Soils and/or Geotechnical Investigation accepted by the City for observation of all grading, site preparation, and compaction testing. Observation and testing shall not be performed by other soils and/or geotechnical engineer unless the subsequent soils and/or geotechnical engineer submits and has accepted by the City, a new Preliminary Soils and/or Geotechnical Investigation. B 10. A grading and drainage plan shall be approved prior to issuance of the building permit. The grading and drainage plan shall indicate how all storm drainage including contributory drainage from adjacent lots is carried to the public way or drainage structure approved to receive storm water. B 11. Stormwater Planning Program LID Plan Checklist (MS4-1 FORM) completed by Engineer of Record shall be copied on the first sheet of Building Plans and on the first sheet of Grading Plans. The form can be found at the following link https://www.dropbox.com/scl/fi/xligonam5i4j ro5oklnw4/MS4-Permit-LID-Determination- Form.pdf?rlkey=zr7tu632u2staheexj6vgvxv &g dl=0 B 12. Exterior exit stairways of the 3-story commercial building shall have a minimum fire separation distance of 10 feet measured at right angles from the exterior edge of the stairway, including landings, to the imaginary lot line between the building and the adjacent hotel per Section 1027.5. B 13. Fire -resistance rating requirements for the westerly exterior wall of the hotel adjacent to the 3- story commercial building the based on fire separation distance of 5 to 20 feet shall comply with Table 705.5 of the Building Code. B 14. Maximum area of exterior wall openings and degree of open protection based on fire separation distance of 5 to 20 feet shall comply with Table 705.8 of the Building Code. B 15. All State of California disability access regulations for accessibility and adaptability shall be complied with. B 16. At least 10 percent but not less than one of the multistory dwellings in condominiums with 4 or more dwelling units shall comply with the housing accessibility requirements per Section I IO2A3.1. The required accessible route shall be provided to connect each accessible/adaptable dwelling unit with including but not limited to the public street sidewalks, accessible parking, and common use facilities such as trach collections, the recreation, center and the dog park per Section 1110A.L B 17. Approval is required from the Los Angeles County Health Department for restaurants. B 18. Approval is required from the Los Angeles County Health Department for public spas, wading pools, and swimming pools. B 19. The property shall be surveyed, and the boundaries marked by a land surveyor licensed by the State of California. B20. Foundation inspection will not be made until the excavation has been surveyed and the setbacks determined to be in accordance with the approved plans by a land surveyor licensed by the State of California. THIS NOTE IS TO BE PLACED ON THE FOUNDATION PLAN IN A PROMINENT LOCATION. Page 2 of 4 V2023 B21. No form work or other construction materials will be permitted to encroach into adjacent property without written approval of the affected property owner. B22. Separate application and plan review is required for Electrical plans. B23. Separate application and plan review is required for Mechanical plans. B24. Separate application and plan review is required for Plumbing plans. B25. Plumbing fixtures shall be provided as required by the Chapter 4 of the California Plumbing Code. Additional fixtures may be required if not in compliance. B26. Project shall comply with the CalGreen Non -Residential mandatory requirements. B27. Project shall comply with the CalGreen Residential mandatory requirements. B28. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of nonhazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive per Section 4.410.2 of the CalGreen Code. B29. When parking is provided, parking spaces for new multifamily dwellings shall meet the accessible parking space requirements per Section 1109A.5 of the Building Code for those designated as visitor parking as well as the requirements under Section 4.106.4.2.2 of the CalGreen Code regarding EV ready spaces and accessible EVCS common for all residences to use. B30. When parking is provided and assigned to hotel guests and employees, EV ready spaces for new hotels shall meet the requirements of Section 4.106.4.2.2 of the CalGreen Code. This requirement shall be separately met from EV charging requirement for the exterior surface parking spaces assigned to commercial building and the spaces within the parking structure as all three are considered separate parking facilities. B31. When parking is provided and designated for commercial building use, EV capable spaces and charging stations for new commercial building shall meet the requirements of Section 5.106.5.3 of the CalGreen Code. This requirement shall be separately met from EV charging requirement for the spaces within the parking structure. B32. The parking spaces within the parking structure as a separate parking facility shall comply with both the accessible parking space requirements per Section 11B-208 of the Building Code and the EV charging requirements per of Section 5.106.5.3 of the CalGreen Code. B33. Prior to the issuance of building permit, a written consent shall be obtained from the current easement holder(s) for any proposed development encroaching into existing easement(s). B34. All fire sprinkler hangers must be designed, and their location approved by an engineer or an architect. Calculations must be provided indicating that the hangers are designed to carry the tributary weight of the water filled pipe plus a 250-pound point load. A plan indication this information must be stamped by the engineer or the architect and submitted for approval prior to issuance of the building permit. Page 3 of 4 V2023 B35. Separate permit is required for Fire Sprinklers. B36. The proposed site is a combination of lots. Parcel merger shall be processed prior to issuance of the building permit. B37.Building permits shall not be issued until the final map has been prepared to the satisfaction of the Building Official. Reviewed by: Building Division/AJ/JK JN:250680 DATE: 7/28/2025 Page 4 of 4 V2023